EN-Rev IM/GN-AM-EN/A12 Copyright © July, 2018. Canadian Solar Inc.
16 |
Use two insertion profiles running perpendicularly to
the long side frame. An additional support bar should
be placed below the module. Use two clamps on the
support bar.
Maximum Load:
Uplift load 2400 Pa
≤
Downforce load 5400 Pa
≤
Use two insertion profiles running parallel to the long
side frame.
Maximum Load:
Uplift load 2400 Pa
≤
Downforce load 4000 Pa
≤
CS1k-MS
Use two insertion profiles running perpendicularly to
the long side frame. An additional support bar should
be placed below the module. Use two clamps on the
support bar.
Maximum Load:
Uplift load 2400 Pa
≤
Downforce load 5400 Pa
≤
Use two insertion profiles running parallel to the long
side frame.
Maximum Load:
Uplift load 2000 Pa
≤
Downforce load 2000 Pa
≤
Use two insertion profiles running perpendicularly to
the long side frame.
Maximum Load:
Uplift load 2400 Pa
≤
Downforce load 4000 Pa
≤
CS1v-MS