background image

K E L O W N A   T P 5 0 0

Kelowna Spa

Owners Manual TP500

210 x 153 x 79cm (83 x 61 x 32")
KH-10041

For Service Support please contact us anytime:  

support.canadianspacompany.com

canadianspacompany.com

Summary of Contents for Kelowna Spa KH-10041

Page 1: ...K E L O W N A T P 5 0 0 Kelowna Spa Owners Manual TP500 210 x 153 x 79cm 83 x 61 x 32 KH 10041 For Service Support please contact us anytime support canadianspacompany com canadianspacompany com...

Page 2: ...will result in voiding the manufacturer s warranty 16 Do not bring any object into the spa that could damage the spa shell 17 Never insert any object into any opening 18 WARNING Do not sit on the spa...

Page 3: ...ated on the outside of spa cabinet used to drain water from the spa A garden hose can be attached to the drain valve EQUIPMENT BAY Located under the spa shell covered by access panels that houses the...

Page 4: ...efore ground construction and the delivery of your spa Your spa must be sited on a solid flat level base which is the same size or larger than the spa The base can be either a 10 15cm concrete slab or...

Page 5: ...es are adhered to A Single Phase connection Most common CONNECTING HOT TUB TO RCD AND CONSUMER PANEL All hot tubs must be wired with the appropriate sized wiring Failure to do so will cause equipment...

Page 6: ...available The spa will heat approximately 1 every 30 minutes per 1 000 litres 6 Check for leaks Although spas are fully checked at the factory shipping delivery might cause a leak Remember to pay part...

Page 7: ...the 3 function test strips at least once a week and if necessary adjust it to 7 2 7 6 Add 10 g m of Chlorine granules after each bathing session Let the circulation pump run for 10 minutes and then c...

Page 8: ...suspended particles C pH high D total alkalinity too high E poor filtration F high dissolved solids Debris in water High concentration of oils and organic contaminants being agitated by jet High calc...

Page 9: ...d component See elimination test section Heater not operating or spa not heating Temperature set to low Set temperature above current water temperature Water level too low Add water until water level...

Page 10: ...ng the pump off and on will help it to prime Do not do this more than 5 times If the pump will not prime shut off the power to the spa and call for service Important A pump should not be allowed to ru...

Page 11: ...he spa started at noon the filter cycles will run as programmed Flip Invert Display Restricting Operation The control can be restricted to prevent unwanted use or temperature adjustments Locking the p...

Page 12: ...ld Mode will last for 1 hour unless the mode is exited manually Drain Mode Some spas have a special feature that allows a pump to be employed when draining the water When available this feature is a c...

Page 13: ...he heater to start it The spa is shut down for 15 min Press any button to reset the heater start up See Flow Related Checks below Heater is Dry MO27 There is not enough water in the heater to start it...

Page 14: ...assage Jet KK 11207 Black Ice 3 Directional Jet KK 11206 Black Ice 10 Waterfall KK 10155 LED Fountain KK 10276 Black Ice Pillow KK 10735 Fixed Speaker KK 10043 Big Red LX 5 hp 2 speed Pump KK 10319 Fi...

Page 15: ...enance or protection is essential Canadian Spa Co warrants the cover for the period of two 2 years Defects caused by misuse or insufficient care are not covered by the warranty TERMS CONDITIONS AND LI...

Reviews: