General Messages

Priming Mode – MO19

Each time the spa is powered up, it will enter Priming Mode. 

The purpose of Priming Mode is to allow the user to run each 

pump and manually verify that the pump is primed (air is 

purged) and water is flowing. This typically requires observing 

the output of each pump separately, and is generally not 

possible in normal operation.  Priming Mode lasts 4 minutes, 

but you can exit it earlier by pressing any Temp button. The 

heater is not allowed to run during Priming Mode.

Water Temperature is Unknown

After the pump has been running for 1 minute, the temperature 

will be displayed.

Too Cold - Freeze Protection

A potential freeze condition has been detected, or the 

Aux Freeze Switch has closed, and the pump is activated, 

depending on how your system was built. The pump is ON 

for at least 4 minutes after the potential freeze condition has 

ended, or when the aux freeze switch opens. In some cases, 

the pump may turn on and off and the heater may operate 

during Freeze Protection. This is an operational message, not 

an error indication.

Water is too Hot (OHS) – MO29

One of the water temp sensors has detected spa water temp 

110°F (43.3°C) and spa functions are disabled. System will 

auto reset when the spa water temp is below 108°F (42.2°C). 

Check for extended pump operation or  high ambient temp.

J29 Warning – MO44

J29 is typically used as a Heater Disable input. As such, it 

should not typically be shorted at power-up. This message 

appears if J29 is shorted at power-up.

Reminder Messages

 

 

 

   Alternates with temperature or 

normal display.

Appears on a regular schedule, e.g. every 90 days.

Change the water in the spa on regular basis to maintain prop-

er chemical balance and sanitary conditions.

 

 

 

    Alternates with temperature or 

normal display.

Appears on a regular schedule, e.g. every 180 days.

Vinyl covers should be cleaned and conditioned for 

maximum life.

    

 

 

 

 

 

  Alternates with temperature or 

normal display.

Appears on a regular schedule, e.g. every 365 days.

Filters should be replaced occasionally to maintain proper spa 

function and sanitary conditions.

Appears on a regular schedule, e.g. every 365 days.

Check your ozone and/or UV generator per your spa 

manufacture’s instructions.

 

 

 

  Alternates with temperature or 

normal display.

Appears on a regular schedule, e.g. every 365 days. Have a 

service technician do a check-up on your spa per your spa 

manufacturer’s instructions.

Heater-Related Messages

Heater Flow is Reduced (HFL) – MO16

There may not be enough water flow through the heater to 

carry the heat away from the heating element. Heater start up

will begin again after about 1 min. See “Flow Related Checks” 

below.

Heater Flow is Reduced (LF)* – MO17

There is not enough water flow through the heater to carry the 

heat away from the heating element and the heater has

been disabled. See “Flow Related Checks” below. After the 

problem has been resolved, you must press any button to reset

and begin heater start up.

Heater may be Dry (dr)* – MO28

Possible dry heater, or not enough water in the heater to start 

it. The spa is shut down for 15 min. Press any button to

reset the heater start-up. See “Flow Related Checks” below.

Heater is Dry* – MO27

There is not enough water in the heater to start it. The spa is 

shut down. After the problem has been resolved, you must

press any button to reset and restart heater start up. See “Flow 

Related Checks”.

R U N

P M P 5

P U R G

A I R

- - - -

- - - C

T O O

C O L D

W A T R

T O O

H O T

- - - -

C H N G

W A T R

C L N

C O V R

C L N

C H E K

  O Z

5 R V C

C H E K

Heater is too Hot (OHH)* – MO30

One of the water temp sensors has detected 118°f (47.8°C) in 

the heater and the spa is shut down. You must press any

button to reset when water is below 108°f (42.2°C). See “Flow 

Related Checks” below.

A Reset Message may Appear with other Messages.

Some errors may require power to be removed and restored.

Flow-Related Checks

Check for low water level, suction flow restrictions, closed 

valves, trapped air, too many closed jets and pump prime.

On some systems even when spa is shut down, some 

equipment may occasionally turn on to continue monitoring 

temperature or if freeze protection is needed.

Sensor-Related Messages

Sensor Balance is Poor – MO15

The temperature sensors MAY be out of sync by or 3°F. Call for 

Service.

Sensor Balance is Poor* – MO26

The temperature sensors ARE out of sync. The Sensor Balance 

is Poor fault has been established for at least 1 hour.

Call for Service.

Sensor Failure – Sensor A: MO31, Sensor B: MO32

A temperature sensor or sensor circuit has failed. Call for 

Service.

Miscellaneous Messages

No Communications

The control panel is not receiving communication from the 

System. Call for Service.

Pre-Production Software

The Control System is operating with test software. Call for 

Service.

°F or °C is replaced by °T

The Control System is in Test Mode. Call for Service.

* This message can be reset from the topside panel with any 

button press.

Memory Failure - Checksum Error* – MO22

At Power-Up, the system has failed the Program Checksum 

Test. This indicates a problem with the firmware (operation

program) and requires a service call.

Memory Warning - Persistent Memory Reset* – MO21

Appears after any system setup change. Contact your dealer or 

service organization if this message appears on more than

one power-up, or if it appears after the system has been run-

ning normally for a period of time.

* This message can be reset from the topside panel with any 

button press.

 

Memory Failure - Clock Error* – MO20  

Contact your dealer or service organization.

Configuration Error – Spa will not Start Up

Contact your dealer or service organization.

A Pump Appears to be Stuck ON – MO34

Water may be overheated. POWER DOWN THE SPA. DO NOT 

ENTER THE WATER. Contact your dealer or service organization.

A Pump Appears to have been Stuck ON when spa was last 

powered - MO35

POWER DOWN THE SPA. DO NOT ENTER THE WATER.

Contact your dealer or service organization.

The water level is too low

Some systems have a water level detect, and this mes-
sage appears if it detects that the water level is too low.

* This message can be reset from the topside panel with any 

button press.

H T R

F L O W

L O S S

- - - -

H T R

- - - -

H T R

M A Y

B E

D R Y

- - - -

W A I T

- - - -

H T R

D R Y

- - - -

H T R

T O O

H O T

- - - -

P R E 5

B T T N

  T O

R 5 E T

- - - -

5 N 5 R

B A L -

A N C E

5 N 5 R

5 Y N C

- - - -

C A L L

  F O R

5 R V C

- - - -

5 N 5 R

  A

- - - -

C A L L

5 R V C

- - - -

  B

  N O

C O M M

B E T A

V E R -

5 I O N

- - - -

M E M

C L O K

F A I L

C N F G

F A I L

C A L L

  F O R

5 R V C

5 T U K

P U M P

H O T

C A L L

5 R V C

W A T R

L E V L

(24)

(25)

Summary of Contents for Kelowna Spa KH-10041

Page 1: ...K E L O W N A T P 5 0 0 Kelowna Spa Owners Manual TP500 210 x 153 x 79cm 83 x 61 x 32 KH 10041 For Service Support please contact us anytime support canadianspacompany com canadianspacompany com...

Page 2: ...will result in voiding the manufacturer s warranty 16 Do not bring any object into the spa that could damage the spa shell 17 Never insert any object into any opening 18 WARNING Do not sit on the spa...

Page 3: ...ated on the outside of spa cabinet used to drain water from the spa A garden hose can be attached to the drain valve EQUIPMENT BAY Located under the spa shell covered by access panels that houses the...

Page 4: ...efore ground construction and the delivery of your spa Your spa must be sited on a solid flat level base which is the same size or larger than the spa The base can be either a 10 15cm concrete slab or...

Page 5: ...es are adhered to A Single Phase connection Most common CONNECTING HOT TUB TO RCD AND CONSUMER PANEL All hot tubs must be wired with the appropriate sized wiring Failure to do so will cause equipment...

Page 6: ...available The spa will heat approximately 1 every 30 minutes per 1 000 litres 6 Check for leaks Although spas are fully checked at the factory shipping delivery might cause a leak Remember to pay part...

Page 7: ...the 3 function test strips at least once a week and if necessary adjust it to 7 2 7 6 Add 10 g m of Chlorine granules after each bathing session Let the circulation pump run for 10 minutes and then c...

Page 8: ...suspended particles C pH high D total alkalinity too high E poor filtration F high dissolved solids Debris in water High concentration of oils and organic contaminants being agitated by jet High calc...

Page 9: ...d component See elimination test section Heater not operating or spa not heating Temperature set to low Set temperature above current water temperature Water level too low Add water until water level...

Page 10: ...ng the pump off and on will help it to prime Do not do this more than 5 times If the pump will not prime shut off the power to the spa and call for service Important A pump should not be allowed to ru...

Page 11: ...he spa started at noon the filter cycles will run as programmed Flip Invert Display Restricting Operation The control can be restricted to prevent unwanted use or temperature adjustments Locking the p...

Page 12: ...ld Mode will last for 1 hour unless the mode is exited manually Drain Mode Some spas have a special feature that allows a pump to be employed when draining the water When available this feature is a c...

Page 13: ...he heater to start it The spa is shut down for 15 min Press any button to reset the heater start up See Flow Related Checks below Heater is Dry MO27 There is not enough water in the heater to start it...

Page 14: ...assage Jet KK 11207 Black Ice 3 Directional Jet KK 11206 Black Ice 10 Waterfall KK 10155 LED Fountain KK 10276 Black Ice Pillow KK 10735 Fixed Speaker KK 10043 Big Red LX 5 hp 2 speed Pump KK 10319 Fi...

Page 15: ...enance or protection is essential Canadian Spa Co warrants the cover for the period of two 2 years Defects caused by misuse or insufficient care are not covered by the warranty TERMS CONDITIONS AND LI...

Reviews: