background image

T H U N D E R   B A Y   S E

Spa Functions

Pumps

Press the “Jets 1” button once to turn pump 1 on or off, and to 

shift between low- and high-speeds if equipped. If left running, 

the pump will turn off after a time-out period. The pump 1 

low-speed will time out after 30 minutes. The high-speed will 

time out after 15 minutes.

The low-speed of pump 1 runs when the other pump is on. If 

the spa is in Ready Mode, Pump 1 low may also activate for at 

least 1 minute every 30 minutes to detect the spa temperature 

(polling) and then to heat to the set temperature if needed. 

When the low-speed turns on automatically, it cannot be deac-

tivated from the panel, however the high speed may be started.

Filtration and Ozone

Pump 1 low and the ozone generator will run during filtration. 

The system is factory-programmed with two filter cycles that 

will run 10 minutes after power-up. The filter duration is 

programmable. At the start of each filter cycle, Pump 2 will run 

briefly to purge its plumbing to maintain good water quality.

Freeze Protection

If the temperature sensors within the heater detect a low 

enough temperature, then the pump(s) automatically activate 

to provide freeze protection. The pump(s) will run either 

continuously or periodically depending on conditions.

In colder climates, an optional additional freeze sensor may 

be added to protect against freeze conditions that may not be 

sensed by the standard sensors. Auxiliary freeze sensor 

protection acts similarly except with the temperature 

thresholds determined by the switch. See your dealer for details.

Clean-up Cycle

When a pump is turned on by a button press, a clean-up cycle 

begins 30 minutes after the pump is turned off or times out. 

The pump and the ozone generator will run for 30 minutes or 

more, depending on the system.

Temperature and Temp Range

Adjusting the Set Temperature

When using a panel with Up and Down buttons (Temperature 

buttons), pressing Up or Down will cause the temperature to 

flash. Pressing a temperature button again will adjust the set 

temperature in the direction indicated on the button. When the 

LCD stops flashing, the spa will heat to the new set 

temperature when required.

If the panel has a single temperature button, pressing the 

button will cause the temperature to flash. Pressing the button 

again will cause the temperature to change in one direction 

(e.g. UP). After allowing the display to stop fl ashing, pressing 

the Temperature Button will cause the temperature to flash 

and the next press will change the temperature in the opposite 

direction (e.g. DOWN). The temperature can be set between 

16°C and 40°C (60°F and 104°F).

Press-and-Hold

If a Temperature button is pressed and held when the 

temperature is flashing, the temperature will continue to 

change until the button is released. If only one temperature 

button is available and the limit of the Temperature Range is 

reached when the button is being held, the progression will 

reverse direction.

PUMPS 

5 HP Big Red 2 Speed pumps

Our 5 HP pump is the most powerful spa 

pump in the market with our oversize 

intakes.  

2” Twin Roto jet

Adjustable and interchangeable jet spins 

and pulsates. The jet can be removed by 

turning it counter-clockwise. To replace the 

jet push inward and clockwise until it clicks 

into place.

3” Directional jet

Adjustable and interchangeable jet features 

a directional nozzle. The jet can be removed 

by turning it counter-clockwise. To replace 

the jet push inward and clockwise until it 

clicks into place.

3” Massage jet

Adjustable and interchangeable jet which 

spins to deliver a soothing massage. The jet 

can be removed by turning it counter-

clockwise. To replace the jet push inward 

and clockwise until it clicks into place.

2” Directional jet

Adjustable and interchangeable jet features a 

directional nozzle. The jet can be removed by 

turning it counter-clockwise. To replace the jet 

push inward and clockwise until it clicks into 

place.

5” (Jumbo) Directional jet

 

Adjustable and interchangeable jet features a 

directional nozzle. The jet can be removed by 

turning it counter-clockwise. To replace the jet 

push inward and clockwise until it clicks into 

place.

5” Massage jet 

Adjustable and interchangeable jet features an 

internal spinner to deliver a low pressure sooth-

ing massage. The jet can be removed by turning 

it counter-clockwise. To replace the jet push 

inward and clockwise until it clicks into place.

2” Point jet

Standard jet is permanently on and supplies 

heated water continually. The jet can be 

removed by turning it counter-clockwise. To 

replace the jet push inward and clockwise 

until it clicks into place.

Air Controller

These are located around the top of your spa. 

Increase or decrease the force of your jets by 

opening or closing the air control valves.

Aroma basket cap

Open cap to place aromatherapy beads. Close 

after use. 

 

Waterfall control 

Located on the topside of the spa, this valve 

adjusts water flow to the waterfall.

HOW JETS WORK

Air is mixed with the water by using the air controls to create massage(s) of varying degrees. Water flow is adjusted by simply 

turning the outer face of the full sized jets. Our hot tubs have a combination of pulsating, rotating, and directional adjustable jets.

 

(15)

Summary of Contents for KH-10030

Page 1: ...T H U N D E R B A Y S E Thunder Bay SE Spa Owners Manual 218x 218 x 82cm 86 x 86 x 33 KH 10030 For Service Support please contact us anytime support canadianspacompany com canadianspacompany com...

Page 2: ...s product yourself as opening or removing audio covers may expose you to dangerous voltage or other risk of injury Refer all servicing to qualified service personnel 12 CAUTION Risk of Electrical Shoc...

Page 3: ...mation Cancellation Policy We require a 48 hour cancellation notice in writing or email prior to your scheduled delivery If we are notified later then a reasonable cancellation charge will be applied...

Page 4: ...in conjunction with the air control system to create an aromatic experience 8 AUDIO VOLUME CONTROL Allows control of MP3 functions from within the hot tub 9 TOPSIDE CONSOLE Button pad and temperature...

Page 5: ...tes ozone to aid in maintaining water quality Ozone helps eliminate organic material such as body oils dead skin cells and hair DRAIN VALVE Valve located on the outside of spa cabinet used to drain wa...

Page 6: ...check with your local council Installation and Ground surface requirements Ground preparation is not included in the sale of any spa or gazebo The location where you are planning to put your spa and o...

Page 7: ...n using the hosepipe which conveniently fits onto the drain valve situated at the base of your spa Ideally you should empty the water to a nearby drain You may wish to purchase a suitable submersible...

Page 8: ...tly into filter housing Push hose pipe into filter housing until it stops Fill up to middle of the skimmer Secure hose placement and turn on water Filling the spa through the filter housing prevents a...

Page 9: ...livery might cause a leak Remember to pay particular attention to barrel unions adjoining the heater Contact your Canadian Spa dealer directly if there is a problem If your new spa pump does not prime...

Page 10: ...wever you have insufficient Amps you will need to use other connection see below 2 Single Phase connection B is used in circumstances where the power supply is limited and where you need more Amps 3 P...

Page 11: ...e Heater is on another service Everything else is on the remaining service For 3 phase connection 1 Completely remove jumper on J51 and J88 2 Completely remove jumper on J52 and J62 3 Make a connectio...

Page 12: ...d relaxation benefits Proper care and maintenance outlined in this section is necessary to ensure the longevity of the spa Damage caused by not following care and maintenance guidelines in this sectio...

Page 13: ...levels using pH Up or decrease with pH Down The granules are dosed directly into the spa water pH Up KA 10051 pH Down KA 10050 FREE Water Test App Chemical Guide Starter Chemical Kit KA 10122 Deluxe...

Page 14: ...inants combined chlorine Chlorine level too high A pH too low B combined chlorine due to high concentration of organic contaminants A high concentration of organic contaminants using up sanitizers B t...

Page 15: ...nge the temperature in the opposite direction e g DOWN The temperature can be set between 16 C and 40 C 60 F and 104 F Press and Hold If a Temperature button is pressed and held when the temperature i...

Page 16: ...use operate Burned out UV bulb Replace unit Component failure Contact dealer No water Flow from Jets Air lock See air lock procedure Adjustable jets turned off Turn jets on Faulty pump or motor Contac...

Page 17: ...every 30 minutes to detect the spa temperature polling and then to heat to the set temperature if needed When the low speed turns on automatically it cannot be deactivated from the panel however the h...

Page 18: ...he control panel will be disabled until power is re established Based on the spa controller configuration will return to the Factory Default Settings After the Pump has been running for 2 minutes the...

Page 19: ...again will initiate a new pump priming session Sometimes momentarily turning the pump off and on will help it to prime Do not do this more than 5 times If the pump s will not prime shut off the power...

Page 20: ...0 minutes after the pump is turned off or times out The pump and the ozone generator will run for 30 minutes or more depending on the system This cycle is used to clean the water within the spa after...

Page 21: ...ng during programmed filter cycles Since polling does not occur the temperature display may not show a current temperature until the heater pump has been running for a minute or two Circulation Mode I...

Page 22: ...o reset when water is below 108 f 42 2 C See Flow Related Checks below A Reset Message may Appear with other Messages Some errors may require power to be removed and restored Flow Related Checks Check...

Page 23: ...gular schedule e g every 30 days Clean the filter media as instructed by the manufacturer Appears on a regular schedule e g every 30 days The Residual Current Device RCD is an important safety device...

Page 24: ...anty becomes void if the spa is placed in commercial application Guarantee of the insulating cover Canadian Spa Co guarantees that the cover the purchase is free from defects in materials and workmans...

Reviews: