Filter Cycle 2 
Optional Filtration

Filter Cycle 2 is OFF by 

default. 

It is possible to 

overlap Filter Cycle 1 

and Filter Cycle 2, 

which will shorten 

overall filtration by the 

overlap amount.

Sub-Menu Detail – Set Filter Cycle 1

Purge Cycles

In order to maintain 

sanitary conditions, the 

pump will purge water 

from their respective 

plumbing by running 

briefly at the beginning of 

each filter cycle. 

If Filter Cycle 1 is set for 

24 hours, enabling Filter 

Cycle 2 will initiate a 

purge when Filter Cycle 2 

is programmed to begin.

Sub-Menu Detail – STANDBY FOR 1 HR

04-11-09

Adjusting Filtration

Main Filtration

Filter cycles are set using a start time and a duration. Start time is indicated by an “A” or “P” in the bottom right corner of the 

display. Duration has no “A” or “P” indication. Each setting can be adjusted in 15-minute increments. The panel calculates the 

end time and displays it automatically.

Hold Mode –
MO37  

Hold Mode is used 

to disable the pump 

during service 

functions like 

cleaning or replacing 

the filter. Hold Mode 

will last for 1 hour 

unless the mode is 

exited manually.

Drain Mode

Some spas have a 

special feature that 

allows a pump to be 

employed when 

draining the water. 

When available, this 

feature is a component 

of Hold Mode. Drain 

Mode will time out 

with Hold Mode.

Sub-Menu Detail – User Preferences

05-15-09

Preferences

F / C

 

 (Temp Display)

Change the temperature between Fahrenheit and Celsius.  

12 / 24 

 

(Time Display) (Not used in Simple Mode)

Change the clock between 12 hr and 24 hr display.

RE-MIN-DER

S  

(Reminders)

Turn the display of reminder messages (like “Clean Filter”) On or Off.

Note: Reminders continue to run in the background even when not displayed. So turning the display of Reminders On or Off does 

not reset any Reminder counts.

CLN-UP

  

(Clean-up)

Clean-up Cycle Duration is not always enabled, so it may not appear. When it is available, set the length of time Pump 1 will run 

after each use. 0-4 hours are available.

Additional Utilities

Utilities 

In addition to INFO, The Utilities Menu contains the following:

A / B

 (

A/B Sensor Temperatures)

When this is set to On, the temperature display will alternate to display temperature from Sensor A and Sensor B in the heater. 

FALT LOG

 

(Fault Log)

The Fault Log is a record of the last 24 faults that can be reviewed by a service tech.

Summary of Contents for Kingston UV Spa

Page 1: ...K I N G S T O N Kingston UV Spa Owners Manual 240 x 216 x 93cm 95 x 85 x 36 KH 10019 For Service Support please contact us anytime support canadianspacompany com canadianspacompany com...

Page 2: ...esult in voiding the manufacturer s warranty 16 Do not bring any object into the spa that could damage the spa shell 17 Never insert any object into any opening 18 WARNING Do not sit on the spa cover...

Page 3: ...cells and hair DRAIN VALVE Valve located on the outside of spa cabinet used to drain water from the spa A garden hose can be attached to the drain valve EQUIPMENT BAY Located under the spa shell cover...

Page 4: ...ound construction and the delivery of your spa Your spa must be sited on a solid flat level base which is the same size or larger than the spa The base can be either a 10 15cm concrete slab or suitabl...

Page 5: ...position Draining your Spa Using drain valve IMPORTANT Before draining your spa shut off the electrical breaker connected to the spa Accessing your spa controls To access the Control Pack undo the 3 s...

Page 6: ...will heat approximately 1 every 30 minutes per 1 000 litres 6 Check for leaks Although spas are fully checked at the factory shipping delivery might cause a leak Remember to pay particular attention t...

Page 7: ...noise Once water comes out tighten the valve back up pump has been bled of the trapped air Chlorine Granules Disinfection To protect your health ensure that your spa water is disinfected thoroughly on...

Page 8: ...h concentration of organic contaminants A high concentration of organic contaminants using up sanitizers B test trips may be ineffective SOLUTION A shock treatment with Granular Chlorine B add Granula...

Page 9: ...ycle duration Based on usage adjust filtration cycle duration High solids content See common water problem section Settings 2 x Pumps standard Simple Options Press Menu button until you reach the mode...

Page 10: ...ump off and on will help it to prime Do not do this more than 5 times If the pump will not prime shut off the power to the spa and call for service Important A pump should not be allowed to run withou...

Page 11: ...tarted at noon the filter cycles will run as programmed Flip Invert Display Restricting Operation The control can be restricted to prevent unwanted use or temperature adjustments Locking the panel pre...

Page 12: ...will last for 1 hour unless the mode is exited manually Drain Mode Some spas have a special feature that allows a pump to be employed when draining the water When available this feature is a component...

Page 13: ...o start it The spa is shut down for 15 min Press any button to reset the heater start up See Flow Related Checks below Heater is Dry MO27 There is not enough water in the heater to start it The spa is...

Page 14: ...A5 In ON position enables Special Amperage Rule B means heater shuts off when pump is on high speed A6 Persistent memory reset Used when the spa is powering up to restore factory settings as determine...

Page 15: ...ce or protection is essential Canadian Spa Co warrants the cover for the period of two 2 years Defects caused by misuse or insufficient care are not covered by the warranty TERMS CONDITIONS AND LIMITA...