K I N G S T O N
K I N G S T O N
Reminder Messages
General maintenance helps.
The display of Reminder Messages can be suppressed by
using the PREF Menu.
Reminder Messages can be chosen individually by the
Manufacturer. They may be disabled entirely, or there may be a
limited number of reminders on a specific model. The
frequency of each reminder (e.g. 7 days) can be specified by
the Manufacturer.
Press a Temperature button to reset a displayed reminder
message.
Alternates with temperature or
normal display.
Appears on a regular schedule, e.g. every 7 days.
Check pH with a test kit and adjust pH with the appropriate
chemicals.
Alternates with temperature or
normal display.
Appears on a regular schedule, e.g. every 7 days.
Check sanitizer level and other water chemistry with a test kit
and adjust with the appropriate chemicals.
Alternates with temperature or
normal display.
Appears on a regular schedule, e.g. every 30 days.
Clean the filter media as instructed by the manufacturer.
Appears on a regular schedule, e.g. every 30 days.
Residual Current Device (RCD) is an important safety device
and must be tested on a regular basis to verify its reliability.
Every user should be trained to safely test the RCD associat-
ed with the hot tub installation. An RCD will have a TEST and
RESET button on it that allows a user to verify proper function.
Warning:
If freezing conditions exist, a RCD should be reset
immediately or spa damage could result. The end user should
always trained to test and reset the RCD on a regular basis.
C H E K
P H
C H E K
C H E M
C L N
(27)
CN6013
DIP Switch Functions
Fixed-function DIP Switches
A1
Test Mode (normally Off).
A2
In “ON” position, add one high-speed pump (or blower) with Heater.
A3
In “OFF” position, add two high-speed pump with Heater.
A4
In “OFF position, add 4 high-speed pump with Heater.
A5
In “ON” position, enables Special Amperage Rule B. means heater
shuts off when pump is on high speed
A6
Persistent memory reset (Used when the spa is powering up to
restore factory settings as determined by software
configuration).
A7
in Off position 1 minute cool down for electric heating on for 5
minute cool down for gas heating.
A8
in Off position not assigned
A9
in Off position not assigned
A10
in Off position not assigned
WARNING:
Setting DIP switches or jumpers incorrectly may cause abnormal
system behaviour and/or damage to system components. Refer to Switchbank
illustration on Wiring Configuration page for correct settings for this system.
A2, A3 and A4
work in combination to determine the number of high-speed
devices and blowers that can run before the heat is disabled i.e A2 and A3 in
the ON position and A4 in the OFF position will allow the heater to operate with
up to 3 high-speed pumps (or two HS Pumps and Blower) running at the same
time. Heat is disabled when the fourth high-speed pump or blower is turned
on.
Note: A2/A3/A4 all off = No heat with any high or blower.
J31
Jumper on 1 pin with 2.0kW or smaller heater
Jumper on 2 pins with 3.0kW or higher heater
SC30 Buss fuse 30 Amp. KK-10382
Glass fuse 10 Amp. KK-10376
f3 fuse topside 1/8. KK-11107
Set ups
(26)
94 x 85"/240 x 216
Brown Cover
KC-10210
Your Hot Tub Parts
2” Massage Jet
KK-11205
Black Ice
2” Directional Jet
KK-11204
Black Ice
5” Directional Jet
KK-11208
Black Ice
5” Massage Jet
KK-11209
Black Ice
3” Massage Jet
KK-11207
Black Ice
3” Directional Jet
KK-11206
Black Ice
10” Waterfall
KK-10155
LED Fountain
KK-10276
Black Ice Pillow
KK-10735
Fixed Speaker
KK-10043
Big Red LX 5 hp
2 speed Pump
KK-10319
Filter Lid
for skimmer
KK-10908
Filter face
KK-10974
Air Control
KK-10790
Waterfall valve
KK-10791
Water Diverter
KK-10788
Aromatherapy Cap
KK-10349
5” LED Light Lens
KK-10299
Balboa CN613
Control 3 Kw heater
KK-10328
BP600/ 2100 (M7)
Heater 3kW
KK-10285
UV + Ozone
KK-KK-11328
UV 15W lamp kit with
sleeve
KK-11202