background image

M O N T R E A L   T P 5 0 0

M O N T R E A L   T P 5 0 0

(22)

(23)

Show and Set Time-of-Day

Be sure to set the Time-of-Day

Setting the time-of-day can be important for determining filtration times and other background features.

When in the TIME menu, SET TIME will flash on the display if no time-of-day is set in the memory.

24-hour time display can be set under the PREF menu. 

Note:

This note refers to systems that do not keep track of Time-of-Day when powered down.

If power is interrupted to such a system, Time-of-Day is not stored. The system will still operate and all other user settings

will be stored. If filter cycles are required to run at a particular time of day, resetting the clock will return the filter times

to the actual programmed periods.

When such a system starts up, it defaults to 12:00 Noon, so another way to get filter times back to normal is to start up

the spa at noon on any given day. SET TIME will still flash in the TIME Menu until the time is actually set, but since the spa

started at noon, the filter cycles will run as programmed.

Flip (Invert Display)

04-11-09

Restricting Operation

The control can be restricted to prevent unwanted use or temperature adjustments. Locking the panel prevents the controller 

from being used, but all automatic functions are still active.

Locking the Temperature allows Jets and other features to be used, but the Set Temperature and other programmed settings

cannot be adjusted.

Temperature Lock allows access to a reduced selection of menu items. These include Set Temperature, FLIP, LOCK, UTIL, INFO 

and FALT LOG

08-06-09

Light Timer 

Programming

Light Timer Option

If LITE TIMR does not appear 

in the Main Menu, the Light 

Timer feature is not enabled 

by the manufacturer. 

When available, the Light 

Timer is OFF by default.

Sub-Menu Detail – Set Light Timer

Unlocking

This Unlock sequence may be used from any screen that may be displayed on a restricted panel. If the panel has both an UP and 

a Down button, the ONLY button that will work in the Unlock Sequence is the UP button.  The temperature will not Unlock if the 

Unlock sequence is done while the panel is displaying “LOCK”.

Sub-Menu Detail – Unlocking the Set Temperature or All Buttons

04-21-09

Summary of Contents for Montreal UV Spa KH-10033

Page 1: ...M O N T R E A L T P 5 0 0 Montreal UV Spa Owners Manual TP500 213 x 153 x 79cm 84 x 61 x 32 KH 10033 For Service Support please contact us anytime support canadianspacompany com canadianspacompany com...

Page 2: ...g will result in voiding the manufacturer s warranty 16 Do not bring any object into the spa that could damage the spa shell 17 Never insert any object into any opening 18 WARNING Do not sit on the sp...

Page 3: ...located on the outside of spa cabinet used to drain water from the spa A garden hose can be attached to the drain valve EQUIPMENT BAY Located under the spa shell covered by access panels that houses t...

Page 4: ...re of the above measurements Always consider during your planning that any decking boards and supporting beams that you install allow access to the sides of your Spa It is the customers responsibility...

Page 5: ...he normal wiring configuration for most household electrical installations 3 wires live neutral and earth If however you have insufficient Amps you will need to use other connection see below Single P...

Page 6: ...e available The spa will heat approximately 1 every 30 minutes per 1 000 litres 6 Check for leaks Although spas are fully checked at the factory shipping delivery might cause a leak Remember to pay pa...

Page 7: ...utive press will alternate through different lighting modes and colours TEMPERATURE UP TEMPERATURE DOWN Chlorine Granules Disinfection To protect your health ensure that your spa water is disinfected...

Page 8: ...o Guides on Canadian Spa Company channel pH LOW pH HIGH pH NORMAL 7 2 7 6 Reduced ef cacy of disinfection Corrosion of metals Skin eye irritation Unpleasant odour Reduced ef cacy of disinfection Skin...

Page 9: ...component See elimination test section Heater not operating or spa not heating Temperature set to low Set temperature above current water temperature Water level too low Add water until water level i...

Page 10: ...rning the pump off and on will help it to prime Do not do this more than 5 times If the pump will not prime shut off the power to the spa and call for service Important A pump should not be allowed to...

Page 11: ...the spa started at noon the filter cycles will run as programmed Flip Invert Display Restricting Operation The control can be restricted to prevent unwanted use or temperature adjustments Locking the...

Page 12: ...the spa started at noon the filter cycles will run as programmed Flip Invert Display Restricting Operation The control can be restricted to prevent unwanted use or temperature adjustments Locking the...

Page 13: ...to start it The spa is shut down for 15 min Press any button to reset the heater start up See Flow Related Checks below Heater is Dry MO27 There is not enough water in the heater to start it The spa...

Page 14: ...3 5 Massage Jet KK 10051 10 Waterfall KK 10155 Bread Pillow KK 010145 Fixed Speaker KK 10862 4 hp 2 6 x 2 2 speed Pump KK 10319 Filter Lid for skimmer KK 10858 SCF filter lid screws 2 per lid KK 1085...

Page 15: ...ntenance or protection is essential Canadian Spa Co warrants the cover for the period of two 2 years Defects caused by misuse or insufficient care are not covered by the warranty TERMS CONDITIONS AND...

Reviews: