background image

EN-Rev IM/GN-AM-EN/A5 Copyright © June 2016. Canadian Solar Inc.

www.canadiansolar.com

| 

7

6 

CS6A-xxxp and CS6A-xxxM

Use four clamps on the long side. Mounting rails 
run perpendicularly to the long side frame. 

Use four clamps on the short side. Mounting rails 

run parallel to the long side frame

A1 range = (0 – 219) mm
Maximum Load:
Uplift load ≤ 2000 Pa
Downforce load ≤ 2000 Pa

 Use four clamps on the short side.

A2 range = (200 – 250) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa

Use four clamps on the short side and two clamps 

on the long side. An additional support bar should 
be placed below the center of the module.

A1

A1

A1

A1

A2

A2

A2

A2

A1 range = (220 – 440) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
A1 range = (270 – 330) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa

A2

A2

A2

A2

A2 range = (0 – 250) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa

A2 range = (200 – 250) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa

A2

A2

A2

A2

CS6k-xxxp, CS6k-xxxM, CS6p-xxxp and CS6p-xxxM

Use four clamps on the long side. Mounting rails 
run perpendicularly to the long side frame.

Use four clamps on the short side. Mounting rails 

run parallel to the long side frame

A1 range = (0 – 239) mm
Maximum Load:
Uplift load ≤ 2000 Pa
Downforce load ≤ 2000 Pa

A2 range = (200 – 250) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa

A1 range = (240 – 330) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa

A1

A1

A1

A1

A1 range = (240 – 550) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa

Use four clamps on the short side.

A2

A2

A2

A2

A2

A2

A2

A2

A2 range = (0 – 250) mm
Maximum Load:
Uplift load ≤ 2000 Pa
Downforce load< 2000 Pa

A2 range = (200 – 250) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa

A2

A2

A2

A2

Use four clamps on the long side. Mounting rails 
run parallel to the long side frame. 

A1

A1

A1

A1

A1 range = (270 – 330) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 4000 Pa

Use four clamps on the short side and two clamps on 

the long side. An additional support bar should be 
placed below the center of the module.

Use four clamps on the long side. Mounting rails 

run parallel to the long side frame

A1 range = (240 – 3300) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 4000 Pa

A1

A1

A1

A1

Summary of Contents for CS6P-P Series

Page 1: ...INSTALLATION MANUAL ANNEX OF STANDARD SOLAR MODULE For professional use only...

Page 2: ...0 ft lbs for M8 coarse thread bolts depending on the bolt class For the bolt grade the technical guideline from the fastener suppliers need to be followed Different recommendations from speciic clampi...

Page 3: ...50 mm Maximum Load Uplift load 2400 Pa Downforce load 5400 Pa CS6U xxxp and CS6U xxxM Use four clamps on the long side Mounting rails run perpendicularly to the long side frame A1 A1 A1 A1 Use four cl...

Page 4: ...xxxM Use four clamps on the long side Mounting rails run perpendicularly to the long side frame Use four clamps on the short side Mounting rails run parallel to the long side frame A1 range 0 239 mm M...

Page 5: ...ting system supplier Each module must be securely maintained through all its length on two opposite sides Install and tighten the insertion profiles to the support structure using the hardware and ins...

Page 6: ...be placed below the module Use two clamps on the support bar Maximum Load Uplift load 2400 Pa Downforce load 5400 Pa Use two insertion proiles running parallel to the long side frame Maximum Load Upli...

Page 7: ...Clamp installation instructions D PanelClaw Inc Standard Claw integrated grounding PanelClaw Grizzly Bear FR Gen II mounting system Grizzly Bear FR Gen II Installation Manual 9910010 Rev A E Array ech...

Page 8: ...53 15 00 Table 1 Mechanical And Electrical Ratings under STC ANNEX C MEChANICAL AND ELECTRICAL RATINgS Module Type Maximum power pmax w Operating voltage vmp v Operating current Imp A Open Circuit vol...

Page 9: ...9 8 94 39 1 9 59 15 00 CS6k 290MS 290 0 32 1 9 05 39 3 9 67 15 00 CS6k 295MS 295 0 32 3 9 14 39 5 9 75 15 00 CS6k 300MS 300 0 32 5 9 24 39 7 9 83 15 00 CS6k 305MS 305 0 32 7 9 33 39 9 9 91 15 00 This...

Page 10: ...ss surface OpERATION pREpARATION Noticeable dirt must be rubbed away by gentle cleaning implement soft cloth sponge or brush with soft bristles Ensure that brushes or agitating tools are not abrasive...