Table 3: Approved bolting methods
Inner four holes installation method
I-A
Middle four holes installation method
M-A
Outer four holes installation method
O-A
Inner four holes installation method
I-B
Middle four holes installation method
M-B
Outer four holes installation method
O-B
Installation Method
Module Types
I-A
I-B
M-A
M-B
O-A
O-B
CS6R-MS/CS6RB-MS
+5400Pa/-
2400Pa
/
/
/
+5400Pa/-
2400Pa
/
CS6RA-MS
+5400Pa/-
2400Pa
/
/
/
/
/
CS6R-MS-HL*
+5400Pa/-
3200Pa
+5400Pa/-
3200Pa
/
/
/
/
CS6W-MS/CS7L-MS/CS7N-MS
/
/
/
/
+5400Pa/-
2400Pa
/
CS6W-T (Preliminary)
/
/
/
/
+5400Pa/-
2400Pa
/
CS6R-T (Preliminary)
+5400Pa/-
2400Pa
/
/
/
+5400Pa/-
2400Pa
/
CS6R-H-AG/
CS6RA-H-AG
+5400Pa/
-2400Pa
+3600Pa/
-2400Pa
/
/
/
/
CS6W-MB-AG
/
/
/
/
+5400Pa/
-2400Pa
/
CS7N-MB-AG (F43 Frame)**/
CS7L-MB-AG (F43 Frame)**
/
/
/
/
+5400Pa/
-2400Pa
+3600Pa/
-2400Pa
CS7N-MB-AG (F46 Frame)***/
CS7L-MB-AG (F46 Frame)***
/
/
/
/
+5400Pa/
-2400Pa
+2800Pa/
-2400Pa
CS6W-TB-AG (Preliminary)
/
/
/
/
+5400Pa/
-2400Pa
/
CS7N-TB-AG/
CS7L-TB-AG
/
/
/
/
+5400Pa/
-2400Pa
+2800Pa/
-2400Pa
Note: The installation method of bolt is based on the experimental results, “/” means not tested. * D-type
washer (as shown on the right) with outer diameter 23mm should be used when uplift load 4000 Pa is
required;** with 35mm height frame;*** with 33mm height frame
D-type washer