6.6.2 Running Message
This function is for maintenance personnel to get operational data such as internal temperature,
Standard NO. etc.
Screens can be scrolled manually by pressing the UP/DOWN keys.
6.6.3 Version
The screen shows the model version and the software version of the Inverter (see Figure 6.7).
Model: 08
Software Version: D20001
Figure 6.7 Model Version and Software Version
6.6.4 Daily Energy
This option is for viewing the energy generation for a specific day.
Press DOWN key to move the cursor to day, month or year, press UP key to change the digit.
Press Enter after the date is selected to display energy for that date.
Press UP/DOWN key to move one date from another.
2015-02-22: 051.3kWh
2015-02-23: 061.5kWh
Figure 6.9 Daily energy
Figure 6.8 Select date for daily energy
YES=<ENT> NO=<ESC>
Select: 2015-02-
23
6. Normal operation
6. Normal operation
6.6.5 Monthly Energy and Yearly Energy
These two options are for viewing the energy generation for selected month or year.
Figure 6.10 Select month for monthly energy
Figure 6.11 Select year for yearly energy
YES=<ENT> NO=<ESC>
Select: 2015-
02
YES=<ENT> NO=<ESC>
Select: 20
15
Press DOWN key to move the cursor, press UP key to change the digit.
Press Enter after the month/year is selected.
2015-02: 0510kWh
2015-01: 0610kWh
Press UP/DOWN key to move from one date from another.
2015: 0017513kWh
2014: 0165879kWh
Figure 6.12 Monthly energy
Figure 6.13 Yearly energy
6.6.8 Warning Message
Message00
:
T: 27-11 D: 7171
6.6.7 Communication Data
The screen shows the internal data of the Inverter (see Figure 6.14), which is for service
technicians only.
01-05: 01 25 E4 9D AA
06-10: C2 B5 E4 9D 55
Figure 6.14 Communication Data
6.6.6 Daily Record
The screen shows history of setting changes. It is only for maintenance personnel
.
The screen shows the internal data of the Inverter (see Figure 6.15), which is for service
technicians only.
Figure 6.15 Warning message
.45.
.44.