.70.
10. Appendices
10.1 Appendix A
AC Terminal
DC Fuse Teminal
Screw For Wiring Box Cover
3-6 Nm
1.5-1.7 Nm
1.8-2.0 Nm
Figure 10.1
Part
Torque
Ground Terminal
3 Nm
Figure 10.2 For all models of inverter
Comments:
A thermal sensor inside the inverter is calibrated to determine ambient temperature. All
inverters will begin a sloped derate at 45C ending at 50% output power at 60C.
Temperatures above 60C and below -25C will derate to 0% output power.
100%
50%
0
45
60
T
(℃)
P
(%)
-25
P/V curve for CSI-50KTL-GS-FLB
Power(W)
50000
17500
200
568
850
990 1000
Voltage(V)
Figure 10.3 CSI-50KTL-GS-FLB Inverter output power by input voltage
P/V curve for CSI-50KTL-GS-B
Power(W)
50000
17500
200
568
850
990 1000
Voltage(V)
Figure 10.4 CSI-50KTL-GS-B Inverter output power by input voltage
10. Appendices
.71.