Combustex BMS-2000 [5.03] Operations Manual -
3. CONFIGURATION
Phone:
403.342.4494
|
Web:
www.canaltaflow.com
For operational, technical or installation assistance, please contact us.
Call Us Toll Free:
1-855-226-2582
• Proportional: The unit will output a 4-20mA loop for the purpose of temperature control.
• On-Off: The unit will cycle the main burner(s) to maintain temperature.
• None: The unit will not monitor the bath T/C, or output any form of temperature control. This
selection is used when temperature control is provided externally to the BMS-2000.
• Yes: Allows access to the main output A/M option via the front screen.
• No: Controller output will stay in auto mode.
This temperature is read off of the dedicated bath thermocouple.
• No: Controller will not use the bath T/C for HTSD.
• Yes: Controller will use the bath T/C for HTSD and will shut down when this configured numeric
temperature setting is crossed. Recommended as a fall back to the bath high temperature contact.
Enables this contact input to be used as a shutdown.
Enables this contact input to be used as a shutdown.
Unit will shut down if the voltage supplied to the controller drops below this value.
This configures the spare 4-20mA input.
• None: Controller will disable this input.
• Indicate Only: Temperature will be displayed on page five.
• Numeric Value: Temperature will be displayed and unit will shut down when the configured
percentage of temperature span setting is crossed.
27
Control Mode
Proportional / On-Off / None
28
Allow Auto / Manual
Yes / No (password protected)
29
Main Bath T/C High Temp SD
No / 0 - 600°C (32 - 1112°F)
30
Bath High Temp (Contact)
Yes / No
31
Bath Low Level
Yes / No
32
Low Voltage
0 - 30 Volts
33
Spare Analog Input SD
None / Indicate Only / 0 - 100%