10
Canarm Tri-Lite 3LEC Series
5
mOUNTING Method 1: I-Beam
5.1 Attach Upper Yoke (to I-Beam)
Measure the flange width of the I-beam you are wanting to hang the
fan from. Compare the I-beam flange width to the diagram below to
determine what mounting holes you will require.
Secure the upper yoke to the I-beam with the “Clamping Plate”
hardware shown below. Tighten the bolts to 90 ft-lb, (122 N-m) using a
3/4” socket and torque wrench.
Proceed to “Hanging the Fan” on pg. 20.
Clamping Plate Hardware (supplied):
a.
(4) 1/2“-13x2.5” GR 5 Bolt
b.
(8) 1/2” Flat Washer
c.
(4) 1/2”-13 Nylock Nut
d.
(2) Clamping Plate
e.
(2) Clamping Shim
Upper Yoke
13-3/4” (45.7cm) x 8” (20.3cm)
I-Beam
Flange Width
Upper Yoke
Mounting Holes
5” (12.7cm)
8-3/8” (21.2cm)
inner holes
>8-3/8” (21.2cm)
9” (22.8cm)
outer holes
Install the “Clamping Shims” only if the thickness of the I-beam flange exceeds 3/8” (1cm). The
mounting holes of the shim are closer to one side than the other. Make sure this side is facing the I-beam.
Installez les cales de serrage que si l’épaisseur de la semelle de la poutre supérieure à 3/8 “(1 cm). Les trous de
fixation de la cale sont plus près d’un côté que de l’autre. Assurez-vous que ce côté est confronté à la poutre
CAUTION/ATTENTION
!
Support Directly From Building Structure.
All mounting instructions assume that the building structure from which the fan will be hung is
of sound construction, undamaged, and capable of supporting loads of up to 650 lbs (295 kg). It
is the sole responsibility of the customer to verify that the building’s structure is adequate for fan
installation. Canarm recommends consulting with a structural engineer prior to fan installation.
Aider directement à la structure du bâtiment.
Toutes les instructions de montage supposent que la structure du bâtiment à partir de laquelle le ventilateur sera
pendu est de construction solide, en bon état, et capable de supporter des charges de jusqu’à 650 lb (295 kg). Il
est de la seule responsabilité du client de vérifier que la structure du bâtiment est suffisante pour l’installation du
ventilateur. Canarm recommande de consulter un ingénieur en structure avant d’attiser installation.
WARNING/ AVERTISSEMENT
!
!
Outer Holes
Inner Holes