PENTA-LITE FANS
5LEC SERIES
6’-16’ Models
HVLS FAN
INSTALLATION
MANUAL
Custom DesignedReduced MaintenanceSTOL Technology
Patent pending
Page 1: ...PENTA LITE FANS 5LEC SERIES 6 16 Models HVLS FAN INSTALLATION MANUAL Custom Designed Reduced Maintenance STOL Technology Patent pending...
Page 2: ...ordance with all applicable codes and standards including fire rated construction Failure to comply could result in personal injury electric shock death fire and or property damage Before attempting i...
Page 3: ...ils et ne pas les utiliser des fins autres que celles pr vues par le fabricant This unit has an unguarded impeller Do not use in locations readily accessible to people or animals Cet appareil poss de...
Page 4: ...8 kg 5L10EC 10 3 0M Fan 8 203 mm 60 1524 mm 9 229 mm 21 lbs 10 kg 5L12EC 12 3 6M Fan 8 203 mm 60 1524 mm 9 229 mm 24 lbs 11 kg 5L14EC 14 4 3M Fan 8 203 mm 60 1524 mm 9 229 mm 27 lbs 12 kg 5L16EC 16 4...
Page 5: ...er Yoke DRAWN DATE 19 04 10 DRAWN BY TH PART NUMBER 6001 S REV _001 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF SKYBLADE FAN COMPANY AND CANNOT BE REPRODUCED OR DISCLOSED TO ANY THIRD PARTY WITHOUT THE...
Page 6: ...r and gear reducer E Airfoil Provides air movement F Wingtip Fence Improves air movement efficiency by reducing drag SERIES 5L06EC 5L08EC 5L10EC 5L12EC 5L14EC 5L16EC DIAMETER 6 1 8M 8 2 4M 10 3 0M 12...
Page 7: ...an closer than 15 of its diameter to any object or its path If this is an issue mounting extension bars and smaller fans are available from Canarm 2 3 Fire Suppression Systems and Fan Placement If ins...
Page 8: ...The event of this max torque being applied is unlikely and will only apply due to a failure of the variable frequency drive and its soft start technology 3 4 Safety Cable A Canarm fan should never be...
Page 9: ...he spacing between multiple fans should be no less than 2 5x the fans diameter when measured from the center of the fans The mounting structure must be able to withstand the torque which is generated...
Page 10: ...een mounting point Minimum Unistrut Size W x H x T Qty of Unistrut Needed 8 2 4m 1 5 8 2 Support Directly From Building Structure All mounting instructions assume that the building structure from whic...
Page 11: ...cture du toit chaque extr mit Fasten the unistrut to the roof structure mounting points at each end with customer supplied Grade 5 hardware as shown Fixez l unistrut aux points de fixation de la struc...
Page 12: ...a single purlin truss or bar joist Ne pas installer le ventilateur partir d une seule panne botte ou solives Unsupported angle iron spans should not exceed 12 3 7m Non pris en charge trav es de fer d...
Page 13: ...r if span is longer than 8 If the angle iron span is 8 2 4m or less proceed to step 5 6a on the following page If the angle iron span is longer than 8 2 4m it is necessary to use double angle irons Lo...
Page 14: ...4 2 1 2 Square Washer see diagram d 4 1 2 Nylock Nut Do not install the fan from a single purlin truss or bar joist Ne pas installer le ventilateur partir d une m me purlin botte ou solives The angle...
Page 15: ...agram d 4 1 2 Nylock Nut Do not install the fan from a single purlin truss or bar joist Ne pas installer le ventilateur partir d une m me purlin botte ou solives The angle irons must be fastened to th...
Page 16: ...de la culasse sup rieure After attaching upper yoke to the angle irons tighten all the bolts securing the angle irons to the roof structure to 90 ft lb 122 N m using a 3 4 socket with torque wrench A...
Page 17: ...re the upper yoke to the I beam with the Clamping Plate hardware shown below Tighten the bolts to 90 ft lb 122 N m using a 3 4 socket and torque wrench Proceed to Hanging the Fan on pg 21 Clamping Pla...
Page 18: ...ced on both sides of the plate for each bolt 5 12 Pre Drill Angle Iron Brackets Holes Your angle iron should be cut to allow 1 2 1 27 cm clearance between the end of the angle iron and the purlin you...
Page 19: ...f the purlin brackets 5 15 Attach Upper Yoke to Angle Iron Attach the upper yolk to the angle irons using the provided 1 2 grade 5 bolts washers and nylock nuts See section 5 7 Attach Upper Yoke to An...
Page 20: ...Bolt b 4 1 2 Flat Washer c 2 1 2 13 Nylock Nut 6 2 Secure Upper Safety Cable Secure the safety cable to the I beam or angle iron by wrapping the safety cable around it threading the cable through the...
Page 21: ...vitesses ce qui peut entra ner des dommages ou une dur e de vie raccourcie Ne pas installer le niveau annulera la garantie du fabricant WARNING AVERTISSEMENT 6 3 Attach the Motor to extension tube At...
Page 22: ...erence Eye Hook illustration on page 23 1 Slide the unlooped end of the guy wire through the eye hook 2 Feed the wire through the loop on the other end of the wire 3 Pull tight so the wire tightens on...
Page 23: ...ing a Beam Clamp b Eye Hook c Gripple Wire Loop Gripple Maximum Angle Gripple Hook Tab Motor Make certain all electrical cords are not obstructed by guy wires Assurez vous que tous les c bles lectriqu...
Page 24: ...Cap 5 16 18 x 3 4 c 10 Zinc Split Lock Washer 5 16 c b a To reduce the risk of personal injury do not bend the blade brackets when installing the brackets balancing the blades or cleaning the fan Do n...
Page 25: ...Canarm Penta Lite 5LEC Series 25 8 INSTALLING BLADES 8 1 Attach Blades to Hub Slide blade onto struts until blade holes and strut holes are aligned...
Page 26: ...Cap 5 16 18 x 3 4 c 12 Zinc Split Lock Washer 5 16 ATTENTION Upon completion of the mechanical installation of the fan and before powering on spin the fan around multiple times by hand to ensure all b...
Page 27: ...nd of blade after blade has been securely attached to the strut Fasten wingtip to blade using a 10 32 X 5 8 Button Cap 8 INSTALLING BLADES 8 3 Wingtip Assembly Wingtip Hardware Kit supplied a 5 10 32x...
Page 28: ...c voltages supply voltage variations voltage dips and frequency time deviation Canarm n est pas responsable des perturbations de tension en r f rence explicite aux interf rences magn tiques lectroniqu...
Page 29: ...rom line inputs at the fan controllers disconnect L1 L2 L3 Wait three 3 minutes for capacitors to discharge to safe voltage levels Darkened display LEDs are NOT an indication of safe voltage levels Fa...
Page 30: ...stallation CAUTION ATTENTION IMPORTANT Check that the correct input voltage is being sent to the fan See rating labels on the motor for acceptable voltage A blown fan due to incorrect input voltage is...
Page 31: ...Input Power Cable Wiring Schematics IMPORTANT Grounding of the incoming power on the motor is required NOTE Canarm Suggests using a field supplied fused disconnect switch 1 Phase Voltage 120V 1Ph 230...
Page 32: ...o a Fire Alarm Panel If the installation of the fan is required to be wired to a fire alarm emergency shut off an external relay will have to be placed by a fire suppression specialist between the vol...
Page 33: ...ding at the motor controller and from the controller to the supply b Do not run your controller and sensitive equipment on the same power line c Install properly sized EM RFI filter d Contact Customer...
Page 34: ...g any noise End of troubleshooting Yes Yes No No No Check splices and wiring at the controller Is the wiring correct No Fix incorrect wiring No Yes Yes No Check controller wiring sheet Is the wiring c...
Page 35: ...lt may be occurring a line reactor may need to be placed to reach correct voltage If the voltage is low at splice of the fan motor Under volt may be occurring a line reactor may need to be placed to r...
Page 36: ...Bar 5 ft Aluminum PP 172 8 8 Mini Blades PP 027 Chassis Silver PP 172 10 10 Mini Blades PP 029 Chassis Bottom Plate Steel PP 172 12 12 Mini Blades BP 031 Purlin Bracket Plate Black PP 172 14 14 Mini B...
Page 37: ...isk of fire electric shock or injury to persons during cleaning and user maintenance Risque d incendie de choc lectrique ou de blessures lors du nettoyage et de l entretien par l utilisateur Disconnec...
Page 38: ...38 Canarm Penta Lite 5LEC Series 12 USER SERVICING INSTRUCTIONS Maintenance Log Replacement Part List DATE MAINTENANCE PERFORMED REPLACEMENT PARTS REQUIRED PART NO DESCRIPTION...
Page 39: ...Canarm Penta Lite 5LEC Series 39 NOTES...
Page 40: ...LIMPL5LEC 0123_04 PHONE 1 613 342 5424 FAX 1 800 263 4598 E Mail hvacsales canarm ca www canarm com...