Canarm Penta-Lite 5LEC Series
17
I-Beam
Flange Width
Upper Yoke
Mounting Holes
5” (12.7cm)
8-3/8” (21.2cm)
inner holes
>8-3/8” (21.2cm)
9” (22.8cm)
outer holes
Outer Holes
Inner Holes
Clamping Plate
5
MOUNTING METHOD 3: I-BEAM
NOTE:
Mounting to I-beams requires the purchase of the I-beam Adapter Kit in lieu of standard Upper
Yoke from Canarm.
5.8 Attach I-Beam Adapter (to I-Beam)
Measure the flange width of the I-beam you are wanting to hang the fan from. Compare the I-beam
flange width to the diagram below to determine what mounting holes you will require.
Secure the upper yoke to the I-beam with the “Clamping Plate” hardware shown below. Tighten the
bolts to 90 ft-lb, (122 N-m) using a 3/4” socket and torque wrench.
Proceed to “Hanging the Fan” on pg. 21.
Clamping Plate Hardware (supplied):
a.
(4) 1/2”-13x2 1/2” GR 5 Bolt
b.
(8) 1/2” Flat Washer
c.
(4) 1/2”-13 Nylock Nut
d.
(2) Clamping Plate
a
b
c
b
d
Install the “Clamping Shims” only if the thickness of the I-beam flange exceeds 3/8” (1cm). The
mounting holes of the shim are closer to one side than the other. Make sure this side is facing the I-beam.
Installez les cales de serrage que si l’épaisseur de la semelle de la poutre supérieure à 3/8 “(1 cm).
Les trous de fixation de la cale sont plus près d’un côté que de l’autre. Assurez-vous que ce côté est
confronté à la poutre
CAUTION/ATTENTION
!