background image

OPERATION

Fans are designed to operate with simple on/off switches, or can be wired into sophisticated controls. Some fan models
are designed to run at variable speed while others are single speed only. Varying a single speed fan will cause the motor
to fail.
Fan labels should indicate whether or not fan is variable speed. If unsure contact a Canarm representative with the fan
model number at our head office.

WARNING: Variable speed fans should have the minimum speed set to open the fan louvers a minimum of 1"
to ensure proper motor cooling and prevent premature motor failure.

These fans are used in a variety of applications and therefore maintenance schedules will vary. In general no more than
1/16" of dirt build-up should occur on blade, motor, guard, and louvers for proper fan operation and to prevent premature
failure. The complete fan should be washed down on a regular basis to maintain the high efficiency of the fan. Particular
care should be taken to clean louvers, fan blades front and back, and front guards for better air moving performance. The
motor should be kept clean to prevent overheating and premature failure. As with all mechanical equipment scheduled
inspections should include checking that all hardware is secure and blade set screws are tight. We suggest as a minimum,
that this be done after every grow out, in livestock applications.

Chart #2

Note:

• NEC Article 310-5 - * Minimum conductor size for general wiring at 115-440VAC is number 14AWG.
• Above wire sizes based on approximate 5% voltage drop during starting; copper conductors; and 75C type THHW, THW, THWN, RH, RHW

insulation etc. For aluminum wire, increase two wire size steps minimum. See NEC Article 310 for ampacities af aluminum conductors.

• Type S, SO, SJ, SJO, etc flexible cable wire sizes. See NEC Article 400 for ampacity.

Table A - Minimum Wire Sizes for Three-Phase Motors

Motor

25 to 50 Feet

100 Feet

150 to 200 Feet

HP

200V

230V

460V

200V

230V

460V

200V

230V

460V

1/8

14(18)* 14(18)*

14(18)*

14(18)*

14(18)*

14(18)*

14(16)*

14(16)*

14(18)*

1/6

14(18)* 14(18)*

14(18)*

14(18)*

14(18)*

14(18)*

14

14(16)*

14(18)*

1/4

14(18)* 14(18)*

14(18)*

14(16)*

14(18)*

14(18)*

14

14

14(18)*

1/3

14(18)* 14(18)*

14(18)*

14(16)*

14(16)*

14(18)*

12

14

14(18)*

1/2

14(16)* 14(18)*

14(18)*

12

14(16)*

14(18)*

10

12

14(18)*

3/4

14(16)* 14(16)*

14(18)*

12

14

14(18)*

10

10

14(16)*

1

14

14(16)*

14(18)*

12

12

14(18)*

8

10

14(16)*

1-1/2

12

14

14(18)*

10

10

14(16)*

6

8

14

2

12

12

14(18)*

8

10

14(16)*

6

6

12

3

10

12

14(18)*

6

8

14

4

6

12

Table B - Minimum Wire Sizes for Single-Phase Motors

Motor

25 to 50 Feet

100 Feet

150 to 200 Feet

HP

200V

230V

460V

200V

230V

460V

200V

230V

460V

1/8

14(18)* 14(18)*

14

14(18)*

12

14(18)*

10

8

14

1/6

14(16)* 14(18)*

12

14(18)*

10

14(16)*

6

6

12

1/4

14

14(18)*

10

14(16)*

8

14

6

4

10

1/3

14

14(18)*

10

14(16)*

8

14

6

4

10

1/2

12

14(18)*

8

14

6

12

4

3

8

3/4

10

14(16)*

6

12

4

10

2

1

6

1

10

14(16)*

6

12

4

10

2

1

6

1-1/2

8

14

6

12

3

8

1

1/0

6

2

8

14

4

10

2

8

1/0

2/0

4

3

6

12

3

8

1/0

6

2/0

4/0

3

WARNING:

Motors are equipped with automatic overload protection and may restart without warning.

Always disconnect power before attempting to service.

WARNING

Moving parts,
disconnect power
before servicing.

!

MAINTENANCE

M0017 - Rev. 5 - Rev Date: 22/04/03

Page 4 of 5

Summary of Contents for PLF09

Page 1: ...ght prepaid and found to be defective This warranty does not include any labour or transportation costs incidental to the removal and reinstallation of the unit at the user s premises Components repaired or replaced are warranted through the remainder of the original warranty period only This warranty applies to the original purchaser user only it is null and void in case of alteration accident ab...

Page 2: ...For each of the 8 turn clips insert the screw through the hole from the back of the flange slide on a nylon washer then the clip and thread the nut Tighten the turn clips with a Phillips screw driver and a 3 8 socket wrench see Figure 1 b PLF09 to PLF24 Models Simply remove the fan from the carton and proceed to next section All Fan Models With the shutter removed slide the fan into the framed ope...

Page 3: ...e sure the cord will not interfere with the blade or louvers To protect the cable place the grommetting supplied over the shutter notch edges see Figure 3 The motors supplied with these fans are dual voltage 120 240V except for 48 Direct Drive 240 volt only but 240V is recommended to reduce power consumption Note Fans are factory pre wired for 240V Follow motor nameplate directions if 120V is desi...

Page 4: ...r 14AWG Above wire sizes based on approximate 5 voltage drop during starting copper conductors and 75C type THHW THW THWN RH RHW insulation etc For aluminum wire increase two wire size steps minimum See NEC Article 310 for ampacities af aluminum conductors Type S SO SJ SJO etc flexible cable wire sizes See NEC Article 400 for ampacity Table A Minimum Wire Sizes for Three Phase Motors Motor 25 to 5...

Page 5: ...Caution Do not use pneumatic grease guns Slowly introduce grease with manual gun otherwise bearing seals will be destroyed REPLACEMENT PARTS See attached appendices for replacement parts ACCESSORIES Canarm provides a full line of controls from simple on off thermostats to sophisticated multiple staging controllers and PC based controllers Winter covers are available for colder climates where the f...

Page 6: ...k Bracket 3 3 G1051 14 PLF Motor Arm 3 4 G1910 14 14 Fan Guard 1 5 G2809 14B PLF Housing 1 6 G2900 14 14 Shutter Assembly 1 7 G2950 14 14 3 45 Rotair Blade 1 No Component Description Qty 8 P1164 E 1 4 HP 1625 RPM 115 230V 3 6 1 8A 1 8 P1168 E3 1 4 HP 1625 RPM 115 230V 1 8 P1155 E Leeson 1 4 HP 1625 RPM 115 230V 1 ...

Page 7: ...ink Bracket 3 3 G1051 16 PLF Motor Arm 3 4 G1910 16 16 Fan Guard 1 5 G2809 16B PLF Housing 1 6 G2900 16 16 Shutter Assembly 1 7 G2950 16 16 3 45 Rotair Blade 1 No Component Description Qty 8 P1164 E3 1 4 HP Max 1625 RPM 115 230V 1 8 P1168 E 1 4 HP 1625 RPM 115 230V 1 8 P1155 E Leeson 1 4 HP 1625 RPM 115 230V 1 ...

Page 8: ...Bracket 3 3 G1051 18 PLF Motor Arm 3 4 G1910 18 18 Fan Guard 1 5 G2809 18B PLF Housing 1 6 G2900 18 18 Shutter Assembly 1 7 G2950 18 18 3 4 Rotair Blade 1 No Component Description Qty 8 P1164 F3 1 3 HP Max 1625 RPM 115 230V 3 6 1 8A 1 8 P1168 F 1 3 HP 1625 RPM 115 230V 1 8 P1155 F Leeson 1 3 HP 1625 RPM 115 230V 1 ...

Page 9: ...Bracket 3 3 G1051 20 PLF Motor Arm 3 4 G1910 20 20 Fan Guard 1 5 G2809 20B PLF Housing 1 6 G2900 20 20 Shutter Assembly 1 7 G2950 20 20 3 45 Rotair Blade 1 No Component Description Qty 8 P1164 F3 1 3 HP Max 1625 RPM 115 230V 3 6 1 8A 1 8 P1168 F 1 3 HP 1625 RPM 115 230V 1 8 P1155 F Leeson 1 3 HP 1625 RPM 115 230V 1 ...

Page 10: ...Guard 1 6 G2809 24B PLF Housing 1 7 P1166 F3 1 3 HP 1100 RPM 115 230V 1 No Component Description Qty 8 G2950 24M 1 7 P1168 G 1 2 HP 1625 RPM 115 230V 1 8 G2948 24338 Rotair Blade 24 6 38 1 Rotair Blade 24 6 45 PLF 24 GVDL 7 P1168 G 1 2 HP 1625 RPM 115 230V 1 8 G2948 24338 Rotair Blade 24 6 38 1 PLF 24 EURO 7 P1155 G Leeson 1 4 HP 1625 RPM 115 230V 1 8 G2948 24338 Rotair Blade 24 6 38 1 ...

Page 11: ...ink Bracket 4 3 G1051 36 PLF Motor Arm 4 4 G1658 36GV 36 Galv Shutter Assembly 1 5 G1900 36 PLF36 Spiral Guard 1 6 G2809 36B PLF Housing 1 7 P1170 36DP 1 2 HP 825 RPM 4 Lug Mount 1 No Component Description Qty 8 P3006 36D 36 S S Blade 3 25 1 8 P3005 36D 36 Galv Blade 3 25 1 8 P3005 36DV 36 Galv Blade 3 19 1 ...

Page 12: ...t Bracket 1 6 G1658 36V 36 GV Shutter Assembly 1 No Component Description Qty 7 G1896 GV 3 Bearing Mount Case 1 8 G1900 36 PLF Guard 1 9 G2458 36 Motor Mount Arm 6 10 G2809 36B PLF Housing 1 11 P2020 45 Motor Pulley 1 12 P3030 36B 36 BD Blade 4 43 Galv 1 13 P9600 Rotary Tensioner 1 14 P2002 216 Bearing 2 Bolt Flange Mount 1 15 P2010 9 9 Pulley 1 16 P2034 AX38 Cogged V Belt AX 38 1 ...