Integrating the Yieldpoint d-Exto MPBX

 

Subsequent channels would be configured with each d-Exto position. An example for channel 2 is shown in 
Figure 9. 

 

(Figure 9) 

 

Multiplexer Configuration

 

If more channels are required than can be supported using Direct Connect configuration then a multiplexer may 
be configured. The multiplexer configuration simply acts as a placeholder for the measurements. 

Use the 

Multiplexers button

 on the Program tab to display the Configure Multiplexers form.  

Select 

Virtual

 as the Model and 

Digital

 as the Gage Type, as shown in Figure 10.  

The Channels configuration will determine how many channel placeholders will be available. If the temperature 
(Upper Channel configuration) of the d-Exto will be read then the maximum Channels will be 16 x 4 Wires. If no 
temperatures are to be read the maximum Channels will be 48 x 2 Wires. 

 

(Figure 10) 

 

 

Summary of Contents for Yieldpoint d-Exto MPBX

Page 1: ...several ranges including 125mm 150mm and 250mm The transducers measure the relative movement between each anchor and the head assembly These measurements provide for understanding deformation of the...

Page 2: ...ure 2 outlines connecting a d Exto to a Campbell Scientific CR1000 using the RSCOM2A converter from RE Smith The RSCOM2A provides a low cost highly configurable signal converter Figure 2 Note Two of t...

Page 3: ...t the serial cable from the RSCOM2A to a computer using a straight through serial cable Launch a terminal emulation program such as HyperTerminal on the computer Configure the port to match the physic...

Page 4: ...e d Exto nodes cannot use the same cable for communications Separate RS 485 RS 232 adaptors and separate COM port connections are required for each d Exto This limits the number of sensors that can be...

Page 5: ...nfiguration form Note the Gage Type Make Model selection for Channel 1 The Units Conversion may also be used to convert the units The default output of the d Exto is millimeters Figure 7 To read the t...

Page 6: ...onfiguration simply acts as a placeholder for the measurements Use the Multiplexers button on the Program tab to display the Configure Multiplexers form Select Virtual as the Model and Digital as the...

Page 7: ...ar for Direct Connect configuration An example for channel 1 is shown in Figure 11 Figure 11 Once all channels are configured press Start Update to create the MCU program download it and start the Mon...