CAUTION
The unit should be
depressurized before
installing or replacing media
Plug the Riser
Tube
Upper
Diffuser
a
The riser
(distributor)
remains inside
the tank seated in
the depression at
the bottom
1
2
3
MANDATORY
Wear a Dust Mask.
Airborne particles could pose
potential health risks.
PREPARATIONS
MEDIA INSTALLATION (WHEN NECESSARY)
When
larger units cannot be loaded due to weight restrictions, media will be shipped pre-measured in separate containers. Follow the steps below
for proper media loading.
NOTE
If severe loss in water pressure is observed when the condition-
er unit is initially placed in service, the conditioner tank may
have been laid on its side during transit. If this occurs, back-
wash the conditioner to ‘reclassify’ the media.
1.
Remove the adaptor and valve from the mineral
tank.Grease the bottom oring of the adaptor
with silicone grease provided
3.
Fill the gravel support bed first.
A large funnel makes filling the
tank much easier. Order part
#99003 separately for your own
funnel. Slowly add the gravel
Depending on the type of system,
add the resin, or media next.
2.
Temporarily plug the open end of the riser tube to ensure
that no resin or gravel falls down into the distribution. The
riser (distributor) remains inside the tank seated in the
depression at the bottom. Plug tube with a tape. Remove
after media is loaded. Ensure the bottom of the riser tube
remains seated in the depression at the bottom of the tank.
Fill tank one-quarter full with water to protect the
distribution tube during gravel installation.