18
19
PRESS SETTINGS KEY
3 SEC TO UNLOCK
AUG/30/2022
12:15AM
REGENERATION
IMMEDIATELY
1.
Press any button to start. The display
may read
PRESS SETTINGS KEY 3
SEC TO UNLOCK
if left untouched for
several minutes.
2.
To unlock, press
button one (1
) and
hold for three (3)seconds. The display
will beep confirming unlock.
3.
Press and hold
button two (2
) to
start Manual Regeneration process.
BACKWASH
10:00 REMAIN
6.
For Upflow valve
press button two
(2
) to manually advance to backwash
position. Downflow valves will
automatically start in backwash position.
4.
Press
button three (3) or four (4
),
choose
REGENERATION IMMEDIATELY
.
5.
Press
button two (2
) to start a
regeneration cycle.
MANDATORY
Be sure to open the bypass inlet very slowly. Do NOT
FULLY open the bypass inlet until there is a steady
stream of water at the drain as this will result in media
being expelled from the unit
START-UP INSTRUCTIONS
Now that your water softener is plumbed into position it is time to start up and program the unit.
STEP 1. ADD WATER TO BRINE TANK
1.
Open the brine tank/cabinet salt lid and fill with water until there is approximately 1” [25.4 mm] of water above
the grid plate.
2.
If there is no grid plate, fill the tank with 3” [75 mm] of water.
Do NOT add salt to the brine tank at this time.
NOTE
If severe loss in water pressure is observed when the
softener unit is initially placed in service, the softener
tank may have been laid on its side during transit. If this
occurs, backwash the softener to ‘reclassify’ the media.
STEP 2. PURGE AIR FROM THE UNIT
7.
Open the bypass inlet very slowly
until there is a steady stream of
water at the drain. Opening the bypass inlet too quickly could result in
resin being expelled from the unit and into the plumbing lines. With the
valve in the backwash position the unit will purge air from the system,
sending it to the drain. This may take longer than the programmed
backwash cycle time, so unplug the power so that the valve will remain in
the backwash position.
8.
With the bypass inlet now fully open, let the system run until all the air is purged and there is a steady stream of water at the drain.
9.
Reconnect the power, press button two (2) to advance to the refill position and allow the unit to refill to 1” [25.4 mm] above the grid
board or 3” [76.2 mm] of water in cabinet models – this may require manually advancing the unit through its cycles more than once.
Alternatively, you can press and hold button 2 (two) to advance to the service position and manually add the required amount of water
as described in step 1.
10.
Allow the unit to return to the SERVICE position.
11.
Slowly open the bypass OUTLET knob until fully open.
Summary of Contents for 85HE
Page 2: ......