background image

8

9

1.

 

Control Valve

2.

 

Pressure Tank

Model 300 will get 

an Adaptor and the 

O-ring shown

Note: Tanks come 

preloaded with media 

with the exception of 

some larger systems 

where the media will 

come in containers. 

This is due to weight 

restrictions. Media will 

need to be loaded 

on site. See steps to 

properly load media 

contained in this 

manual. 

,03257$17

3/($6((1685(7+($77$&+('

78%(67,))(1(5,6,16(57('

,1727+(%5,1(/,1(%()25(

7,*+7(1,1*

7+(187

There are 8 Red clips. Please 

check to make sure you 

have all of them.

3. 

Parts Box

60090003

2X 1” Straight 

Adapter

60010006 

Bypass Tool

60010026

O-Rings Attached

60090010

2 X 3/4” 

Elbow 

Adapter

60090026

Elbow, Inlet/Outlet, 1” NPT 
Optional with some units

60010052

Transformer

92360

Grease  

Packet

Brine Tank 

(Round or 

Square)

Brine Tank 

Tubing

Brine Well/

Safety Float

Brine Tank Lid

Grid (Round or Square)

Grid Legs (3 for 

Round and 4 for 

Square)

4. 

Brine Tank Assembly (Round Brine Tank Shown))

,03257$17

3/($6((1685(7+($77$&+('

78%(67,))(1(5,6,16(57('

,1727+(%5,1(/,1(%()25(

7,*+7(1,1*

7+(187

Note: For upflow water softeners, a problem water injector 

kit is enclosed. See Problem Water Injector Kit page for 

usage information.

UNPACKING/INSPECTION

 

WARNING

RISK OF CHOKING

  

Discard all leftover parts and packaging materials after 

installation. Small parts could be a choking hazard.

 

NOTE

Canature is NOT responsible for  

damages in transit.

 

NOTE

Due to transportation and climatic conditions, all 

connections, including the valve to the tank, need to 

be checked at time of installation and hand  

tightened, where necessary.

Be sure to check the entire unit for any shipping damage or parts loss.  Also note damage to the shipping cartons.  Contact the transportation 

company for all damage and loss claims. 

The manufacturer is not responsible for damages in transit

.

Small parts, needed to install the softener, are in a parts box. To avoid loss of the small parts, keep them in the parts bag until you are ready to 

use them.

 

What is included in the box?

For Models 075,100,150, 200, 300 you will expect the following:

1.

 Control Valve* 

2. 

Pressure Tank 

3. 

Parts Box 

4. 

Brine Tank Assembly 

5. 

Drain Hose & Clamp (Not included in some brands) 

6. 

Owners Manual

*All units (75, 100, 150, 200) are pre assembled with control 

valve installed on the tank, no assembly required.

Summary of Contents for 85HE

Page 1: ...lly before operation 4 Avoid pinched O rings during installation by applying NSF certified lubricant to all seals provided with install kit 5 This system is not intended for treating water that is mic...

Page 2: ......

Page 3: ...RATE INFORMATION 8 FEED WATER PARAMETERS 8 UNPACKING INSPECTION 9 BEFORE INSTALLATION 10 PREPARATIONS 11 PLANNING YOUR INSTALLATION 14 INSTALLATION STEPS 16 UNDERSTAND THE SCREEN KEYPAD CONFIGURATION...

Page 4: ...he warranty The warranty provided gives you specific legal rights and otherwise limits your legal rights to the extent permitted by law By installing and or using this product you are accepting these...

Page 5: ...e Records Contacts section as they will be important if you need to troubleshoot NOTE For cabinet models the model number and the system serial number are located under the salt lid FIND AND RECORD VA...

Page 6: ...43 C or 40 F 110 F Do NOT expose softener to freezing temperatures Discharge lines exposed to freezing temperatures should be positioned with a downward slope Do NOT expose softener to direct sunligh...

Page 7: ...ond will be 70 of capacity The unit counts down to the end of the 70 and then calculates how much of the 30 you used reserve It then adjusts the brine amount accordingly and regenerates that evening T...

Page 8: ...worst case scenario where water hardness fluctuates Peak Flow Maximum flow that has gone through the softener Manual Regen Delay Generally used after servicing the valve so that it will regenerate at...

Page 9: ...m water injector kit is enclosed See Problem Water Injector Kit page for usage information UNPACKING INSPECTION WARNING RISK OF CHOKING Discard all leftover parts and packaging materials after install...

Page 10: ...to the pipe as excessive heat can damage them Softener resins will degrade in the presence of chlorine or chloramines above one 1 ppm If you have anything in excess of this amount you will experience...

Page 11: ...er part 99003 separately for your own funnel Slowly add the gravel Depending on the type of system add the resin or media next Support Bed Gravel Media MANDATORY Wear a Dust Mask Airborne particles co...

Page 12: ...ve the tape from the top of the riser tube Carefully position the valve over the riser tube inserting riser into the internal O ring Turn the valve clockwise into the threads of the tank until secure...

Page 13: ...ide the brine tank 6 For installation of brine tank at the installation site pull the other end of the brine tube from the hole on the brine tank The completed assembly is below 3 Place the brine grid...

Page 14: ...in and a 120 volt AC electrical outlet 6 Softeners should be located before the water heater on the supply line If closer than three 3 metres 10 feet install a check valve in accordance with local plu...

Page 15: ...ector Detail AC 120V 10A Current Protect Socket BrineValve Connector Detail Twin Tank Softener Laundry Stack AC 120V 10A Current Protect Socket Inlet Outlet Optional Overflow Assembly 5 8 Overflow Lin...

Page 16: ...nnections straight or elbow plumbing adaptors 3 Apply the supplied lubricant 92360 to the O rings of the fittings 4 Connect the supplied straight or elbow plumbing adaptors to the bypass with red clip...

Page 17: ...re bypass knobs are completely open otherwise the untreated water may enter through the valve OPEN OPEN CLOSE OPEN OPEN CLOSE OPEN OPEN CLOSE SERVICE INLET OUTLET INLET OUTLET BYPASS INSTALLATION STEP...

Page 18: ...e 13 Delayed regeneration 14 RegenerationTime time of day when backwash starts 15 Refill time 16 Valve mode 17 Valve ID UNDERSTAND THE SCREEN KEYPAD CONFIGURATION Keypad Legend the terminology used on...

Page 19: ...add salt to the brine tank at this time NOTE If severe loss in water pressure is observed when the softener unit is initially placed in service the softener tank may have been laid on its side during...

Page 20: ...m Manganese x 8 __ grains of hardness These numbers can be found on your water analysis report and the equivalent grains of hardness should be added to your total hardness number The new sum of these...

Page 21: ...1 for three seconds 3 to unlock 2 After three 3 seconds the display will beep confirming unlock 3 Press and hold button one 1 for three seconds 3 until you hear a beep This will unlock the SETTINGS m...

Page 22: ...or four 4 key to change WATER SOURCE value For problem water set to WELL OTHER For clean city water choose MUNICIPAL REGEN TIME 02 00 AM LOAD DEFAULT NO REGEN TIME 02 00 PM PROGRAMING COMPLETE 23 Now...

Page 23: ...event bacteria growth from stagnant water This mode is also recommended for filters as certain types of filter media can cement or harden during long periods of non use The factory setting for Smart C...

Page 24: ...LEM WATER INJECTOR KIT For use on upflow softeners only IMPORTANT If the water source this water softener is being applied on is not municipal water and contains up to 2 0 mg l ppm of ferrous Clear Wa...

Page 25: ...ess button two 2 until past PROGRAMMING COMPLETE PRESS SETTINGS KEY 3 SEC TO UNLOCK 1 The display may read PRESS SETTINGS KEY Press button one 1 for three seconds 3 to unlock 2 After three 3 seconds t...

Page 26: ...the water heater OFF and shut the heater inlet water valve OFF 2 Drain hot water tank completely OPEN the InletWaterValve allowing the heater tank to be refilled with iron free water Continue flushin...

Page 27: ...requency Maintenance materials Please see Common Spare Parts CARE OF YOUR SOFTENER To retain the attractive appearance of your new water softener occasionally clean it with a mild soap solution Do NOT...

Page 28: ...tions happen or the unit fails to regenerate for any other reason correct the problem first then regenerate the unit manually Regenerate two times in a row to restore the reserve capacity and bring th...

Page 29: ...er and drill 1 Measure 2 inches from the top of the tank beside the oblong molding 3 Install the holder 5 Take off the small hole cover on the BrineWell lid 4 Hang the Res Care bottle on the hanger 6...

Page 30: ...h 64 oz Rescare SERVICING YOUR CONTROL VALVE BEFORE SERVICING YOU WILL NEED TO 1 Shut the water supply to the softener OFF put the softener into the BYPASS position 2 Relieve water pressure in the sof...

Page 31: ...l and repeat until finishing with a seal Important use the specialized end spacer and note it s placement 6 Lubricate the piston assembly with silicone lubricant Part 92360 and then replace the Piston...

Page 32: ...salt and silt will restrict or clog the injector A clean water supply and pure salt will prevent this from happening The injector assembly is located on the right side of the control valve when facing...

Page 33: ...will restrict or clog the injector A clean water supply and pure salt will prevent this from happening The injector assembly is located on the right side of the control valve when facing your softener...

Page 34: ...tion Unplug power for 30 seconds then reconnect If the alarm continues contact your authorized installer UNIT REGENERATES BUT DOES NOT USE SALT Drain line flow control is plugged Clean or replace inje...

Page 35: ...be running at the drain 1 Replace the motor and transformer if unable to determine the output of the transformer separately 2 Contact your authorized installer for parts and or assistance COMMON SPAR...

Page 36: ...y force of nature is not covered in this warranty At our sole discretion we will repair or replace defective parts if our warranty department determines it to be defective under the terms of this warr...

Reviews: