The table below can be used to help deter-
mine the frequency of regeneration for Multi-
Media and Taste & Odour filters. Use this ta-
ble as a guide since individual circumstances
will require more or less frequent regenera-
tions. This can be adjusted by the home
owner to suite their individual needs with fre-
quencies available from 1 – 99 days.
To prevent bacterial build up in the media,
activated carbon filters should not exceed 6
days between backwashes.
To set a Neutralizing filter, follow the table
under mild conditions
Sediment
Mild
Average
Extreme
Taste Odor
Mild
Average
Extreme
No. Of Per-
sons
Days Between Back Wash (Regenerations)
2
6
6
6
6
6
6
6
6
6
6
4
4
4
4
4
4
3
6
6
6
6
4
4
4
4
4
4
3
3
3
3
3
3
4
6
6
6
6
4
4
4
3
3
3
2
2
2
2
2
2
5
6
6
4
4
3
3
3
3
2
2
2
2
1
1
1
1
6
6
6
4
4
3
3
3
2
2
2
2
1
1
1
1
1
7
6
4
4
3
3
2
2
2
1
1
1
1
1
1
1
1
8
6
4
4
3
2
2
2
2
1
1
1
1
1
1
1
1
9
4
4
3
3
2
2
1
1
1
1
1
1
1
1
1
1
10
4
3
3
2
2
1
1
1
1
1
1
1
1
1
1
1
Backwash Frequency
Programming Instructions
TIME OF DAY, YEAR, MONTH, DAY,
Time of day is for normal operation of system and the scheduling of the
regeneration time. The date is used in a diagnostic function to track the
last time the system regenerated.
REGEN DAYS
This value is the number of days between regenerations or back washes to
clean the filters.
GALLONS
Default value is OFF. Adjust the GALLONS to set the capacity. This will
cause the unit to regenerate either when the gallons remaining goes to
zero or the days between regeneration is zero. Which ever occurs first.
REGEN TIME
This setting determines the time of day to perform a scheduled regenera-
tion. The normal regen time for a filter is 12:00 AM.