Control Operation During A Power Failure

In the event of a power failure, the valve will keep track of the time and day for 48 hours.  
The programmed settings are stored in a non-volatile memory and will not be lost during a 
power failure.  If power fails while the unit is in regeneration, the valve will finish regenera-
tion from the point it is at once power is restored.  If the valve misses a scheduled regen-
eration  due  to  a  power  failure,  it  will  queue  a  regeneration  at  the  next  regeneration  time 
once power is restored. 

Main Display

About The System 

Periodically the filter will require a back wash to clean the trapped particles and unpack the 
filter bed to restore the system flow rates.  The table below explains the regeneration steps. 

Regeneration Process

The  main  display  page  will  pause  on  the  Date  and  Time  page  for  5  seconds.    Then  it  will 
continually  scroll  through  all  of  the  system  diagnostic  display  pages.    Depending  on  the 
Valve Type  some pages  will  not be displayed.   To manually scroll through the  diagnostics, 
press the down or up key.  To reset the TOTAL REGENS, TOTAL GALLONS OVER RUN TO-
TAL, or PEAK flow rates, press and hold the MENU until the value changes to zero. 

PARAMETER

DESCRIPTION

JULY/17/2012

8:30 PM

TOTAL 1,500 GAL

REMAIN 1,200 GAL

LAST REGEN

9/24/12

TOTAL REGENS

10

TOTAL GALLONS

001590 GAL

TOTAL 4 DAYS

REMAIN 3 DAYS

OVER RUN TOTAL

0000 GAL

CURRENT 1.5 GPM

PEAK 6.5 GPM

DELAYED REGEN

OFF

REGEN TIME

12:00 AM

VALVE MODE

B.W. FILTER

The current setting for regeneration time.

The current setting of the valve mode.

The total number of regenerations.

The total amount of gallons treated by the system.

The total amount of water that has exceeded the system capacity over the last 4 
regenerations.  When remaining goes to zero, the gallons used will be added to over run total.

The current flow rate and the peak flow rate since the last regeneration.

Advises whether a delayed regeneration has been scheduled manually or automatically.

Month, Day, Year, Time

The number of days remaining before regeneration.  This option is only in filter mode.

The total amount is the system capacity when fully regenerated.  The remaining is the 
capacity left in the system.

The date of the last regeneration.

Summary of Contents for 785

Page 1: ...ying provided with install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfectio...

Page 2: ...anual must be followed to minimize the risk of electric shock property damage or personal injury Be sure to check the entire unit for any shipping damage or parts loss Also note damage to the shipping...

Page 3: ...Excessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all gov erning codes and ordinances Use only lead free solder and flux for all sweat so...

Page 4: ...edia Volume Cubic Feet 0 75ft3 1 0ft3 1 5ft3 2 0ft3 3 0 ft3 Filter Tank Size 8x44 9x48 10x54 12x52 14x65 Tank Jacket Media Loaded Yes Yes Yes No No Shipping Weight 50lbs 60lbs 78lbs 95lbs 138 lbs Serv...

Page 5: ...ilitates the removal of iron and manganese by raising the pH This enables an iron filter to be used Periodic backwashing cleans the bed Addi tional media may be required six months to two years after...

Page 6: ...Put the filter in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for wa ter damage A 120 volt electric outlet to plug the in cluded transform...

Page 7: ...pump must be capable of providing the backwash flow rates indicated on page 4 Check Your Pumping Rate Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipm...

Page 8: ...when soldering pipes that are connected to the valve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also inclu...

Page 9: ...9 Filter Installation...

Page 10: ...locked press SETTINGS for 3 seconds to unlock Press and hold the MANUL REGEN Key for 3 seconds Press any key to skip the BRINE cycle 4 Open the inlet on the bypass valve slightly and very slowly allow...

Page 11: ...3 2 2 2 2 2 2 5 6 6 4 4 3 3 3 3 2 2 2 2 1 1 1 1 6 6 6 4 4 3 3 3 2 2 2 2 1 1 1 1 1 7 6 4 4 3 3 2 2 2 1 1 1 1 1 1 1 1 8 6 4 4 3 2 2 2 2 1 1 1 1 1 1 1 1 9 4 4 3 3 2 2 1 1 1 1 1 1 1 1 1 1 10 4 3 3 2 2 1 1...

Page 12: ...l through the diagnostics press the down or up key To reset the TOTAL REGENS TOTAL GALLONS OVER RUN TO TAL or PEAK flow rates press and hold the MENU until the value changes to zero PARAMETER DESCRIPT...

Page 13: ...to 30 minutes During this time you may hear water running intermittently to the drain Manual Bypass In the case of emergency you can isolate your water filter from the water supply using the bypass va...

Page 14: ...r to determine the expected life of your media bed AC Taste and Odor Filter under normal operating conditions the effective life of the filter media is approximately one to three years depending on th...

Page 15: ...2 Fine gravel 2 Fine gravel 3 Carbon 3 Calcite Once this is done the rag or cork should be removed from the distributor tube Clean off the top of the tank Finally place the control valve on the tank a...

Page 16: ...Main Repair Parts Replacing Drain Line Flow Control DLFC 1 Remove the red clip that secures the drain line elbow 2 Remove the BLFC washer from the elbow fitting 3 Reassemble using the reverse procedu...

Page 17: ...17 Filter Exploded View Brine tank for softener system only...

Page 18: ...18 A A A B D F E A C Main Repair Parts Connectors...

Page 19: ...TOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032 INJECTOR SET 2 BLUE 6001013...

Page 20: ...0 1 5056063 O Ring 78 74 5 33 A21 1 26010103 O Ring 25 3 55 A22 1 7060007 Valve Bottom Connector A23 1 13000426 Screw ST2 9X13 Large Washer A24 2 5031022 O Ring 32 3 A25 1 5031021 O Ring 18 3 A26 1 50...

Page 21: ...21 Power Head Exploded View...

Page 22: ...6 Screw ST2 9X13 Large Washer A24 2 5056139 Washer 3x13 B09 1 5030007 BNT85 Main Gear B10 1 5030005 BNT185 Housing B11 1 5031017 BNT85HE Brine Gear Downflow B12 1 5010023 Magnet 3 2 7 B13 1 5056141 Wa...

Page 23: ...23 Trouble Shooting...

Page 24: ...mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times operated in accordance with specifications and not...

Reviews: