background image

14  

Maintenance 

Care of Your System

To  retain  the  attractive  appearance  of  your  new  water  filter,  clean  occasionally  with  mild 
soap solution.  Do not use abrasive cleaners, ammonia or solvents.  Never subject your sof-
tener to freezing or to temperatures above 100°F. 

Maintenance  of  your  new  water  filter  requires  very  little  time  or  effort  but  it  is  essential. 
Regular maintenance will ensure many years of efficient and trouble-free operation. 

1. Periodically make sure your pump is performing satisfactorily to ensure sufficient water is 

available for backwashing the filter. 

2. Periodically  test  your  raw  and  filtered  water  to  ensure  conditions  are  still  the  same  for 

your original settings and that the unit is working they way it is intended to.  Water test-
ing is often the best way to determine when the filter media will require replacement. 

3. Periodically check that the drain line is clear and free from any obstructions. 

NE  -  Neutralizing  Filter 

- the media bed in a neutralizing filter is slowly dissolved and has 

to be replaced. The frequency of replacement varies, depending on water quality - consult 
your dealer to determine the expected life of your media bed. 

AC  -  Taste  and  Odor  Filter 

- under normal operating conditions the effective life of the 

filter  media  is  approximately  one  to  three  years,  depending  on  the  water  quality,  after 
which, taste and odor problems  may return. When this  happens, contact your dealer for a 
replacement media bed. 

MM  -  Sediment  and  Turbidity  Filter 

- under normal operating conditions, the media 

should never need to be replaced. However, if you experience pressure loss and cannot cor-
rect  it  with  a  manual  regeneration,  your  media  bed  may  need  replacing  -  contact  your 
dealer. 

Replacing the Media Bed

Check to ensure all media parts are received. 

The first step in replacing the media bed is to shut off the water supply  to the filter. Then 
place the unit into the backwash position to release any pressure in the lines.  At this point, 
you  must  disconnect  the  plumbing  from  the  inlet  and  outlet.    Then  unscrew  the  control 
valve from the fibreglass tank.  Once this has been done, remove the distributor tube.  Then 
you can remove the filter media and two types of gravel from the tank.  The quickest way to 
do this is by simply tipping the tank upside down into a large drum or pail. The tank must 
be rinsed out completely and have no media or gravel left in it at all. 

Installation & Replacement Filter Media Pak

Summary of Contents for 785

Page 1: ...ying provided with install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfectio...

Page 2: ...anual must be followed to minimize the risk of electric shock property damage or personal injury Be sure to check the entire unit for any shipping damage or parts loss Also note damage to the shipping...

Page 3: ...Excessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all gov erning codes and ordinances Use only lead free solder and flux for all sweat so...

Page 4: ...edia Volume Cubic Feet 0 75ft3 1 0ft3 1 5ft3 2 0ft3 3 0 ft3 Filter Tank Size 8x44 9x48 10x54 12x52 14x65 Tank Jacket Media Loaded Yes Yes Yes No No Shipping Weight 50lbs 60lbs 78lbs 95lbs 138 lbs Serv...

Page 5: ...ilitates the removal of iron and manganese by raising the pH This enables an iron filter to be used Periodic backwashing cleans the bed Addi tional media may be required six months to two years after...

Page 6: ...Put the filter in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for wa ter damage A 120 volt electric outlet to plug the in cluded transform...

Page 7: ...pump must be capable of providing the backwash flow rates indicated on page 4 Check Your Pumping Rate Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipm...

Page 8: ...when soldering pipes that are connected to the valve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also inclu...

Page 9: ...9 Filter Installation...

Page 10: ...locked press SETTINGS for 3 seconds to unlock Press and hold the MANUL REGEN Key for 3 seconds Press any key to skip the BRINE cycle 4 Open the inlet on the bypass valve slightly and very slowly allow...

Page 11: ...3 2 2 2 2 2 2 5 6 6 4 4 3 3 3 3 2 2 2 2 1 1 1 1 6 6 6 4 4 3 3 3 2 2 2 2 1 1 1 1 1 7 6 4 4 3 3 2 2 2 1 1 1 1 1 1 1 1 8 6 4 4 3 2 2 2 2 1 1 1 1 1 1 1 1 9 4 4 3 3 2 2 1 1 1 1 1 1 1 1 1 1 10 4 3 3 2 2 1 1...

Page 12: ...l through the diagnostics press the down or up key To reset the TOTAL REGENS TOTAL GALLONS OVER RUN TO TAL or PEAK flow rates press and hold the MENU until the value changes to zero PARAMETER DESCRIPT...

Page 13: ...to 30 minutes During this time you may hear water running intermittently to the drain Manual Bypass In the case of emergency you can isolate your water filter from the water supply using the bypass va...

Page 14: ...r to determine the expected life of your media bed AC Taste and Odor Filter under normal operating conditions the effective life of the filter media is approximately one to three years depending on th...

Page 15: ...2 Fine gravel 2 Fine gravel 3 Carbon 3 Calcite Once this is done the rag or cork should be removed from the distributor tube Clean off the top of the tank Finally place the control valve on the tank a...

Page 16: ...Main Repair Parts Replacing Drain Line Flow Control DLFC 1 Remove the red clip that secures the drain line elbow 2 Remove the BLFC washer from the elbow fitting 3 Reassemble using the reverse procedu...

Page 17: ...17 Filter Exploded View Brine tank for softener system only...

Page 18: ...18 A A A B D F E A C Main Repair Parts Connectors...

Page 19: ...TOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032 INJECTOR SET 2 BLUE 6001013...

Page 20: ...0 1 5056063 O Ring 78 74 5 33 A21 1 26010103 O Ring 25 3 55 A22 1 7060007 Valve Bottom Connector A23 1 13000426 Screw ST2 9X13 Large Washer A24 2 5031022 O Ring 32 3 A25 1 5031021 O Ring 18 3 A26 1 50...

Page 21: ...21 Power Head Exploded View...

Page 22: ...6 Screw ST2 9X13 Large Washer A24 2 5056139 Washer 3x13 B09 1 5030007 BNT85 Main Gear B10 1 5030005 BNT185 Housing B11 1 5031017 BNT85HE Brine Gear Downflow B12 1 5010023 Magnet 3 2 7 B13 1 5056141 Wa...

Page 23: ...23 Trouble Shooting...

Page 24: ...mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times operated in accordance with specifications and not...

Reviews: