15  

Loading the Media Pak

Place  the  distributor  tube  back  down  the  center  of  the  tank.    NOTE:  the  top  of  this  tube 
should  be  plugged  with  a  rag  or  cork  to  prevent  media  from  entering.  Pour  the  bag  of 
coarse gravel into the tank, and then pour the bag of fine gravel into the tank. 

It is important that the distributor tube is not moved or pulled out as it is not possible to put 
it down to the bottom of the tank once gravel or media are in the tank. 

Finally pour the larger bag(s) of media into the tank in the following order: 

Multimedia Filters 

1. 

Coarse gravel (1/2 x 1/4)   

4. 

Fine garnet (30 x 40) 

2. 

Fine gravel (1/8 x 1/16)    

5. 

Fine filter sand (.45 x .55) 

3. 

Coarse gravel (8 x 12)  

 

6. 

Anthrafilt 

ACF Carbon Filters Neutralizing Filters 

1. 

Coarse gravel    

1. 

Coarse gravel  4. 

Mag Oxide 

2. 

Fine gravel  

 

2. 

Fine gravel 

3. 

Carbon    

 

3. 

Calcite 

Once  this  is  done,  the  rag  or  cork  should  be  removed  from  the  distributor  tube.  Clean  off 
the  top  of  the  tank.    Finally  place  the  control  valve  on  the  tank  and  on  to  the  distributor 
tube. Tighten the control valve on to the tank. Connect or reconnect the inlet and outlet and 
drain. The control valve should be in the backwash position. Slowly open the inlet valve wa-
ter supply and slowly fill the filter tank until water appears at the open drain line. Return the 
control to the service position and shut the inlet off for approximately one hour to allow the 
media to soak in the water. 

After one hour, turn inlet water on slowly and place the control into the backwash position 
and  plug  the  unit’s  electrical  cord  into  a  constant  power  source.  Let  the  unit  continue 
through  its  regeneration  cycle  automatically.    The  regeneration  is  necessary  so  all  media 
fines are backwashed down the drain to ensure clean filtered water. 

Summary of Contents for 785

Page 1: ...ying provided with install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfectio...

Page 2: ...anual must be followed to minimize the risk of electric shock property damage or personal injury Be sure to check the entire unit for any shipping damage or parts loss Also note damage to the shipping...

Page 3: ...Excessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all gov erning codes and ordinances Use only lead free solder and flux for all sweat so...

Page 4: ...edia Volume Cubic Feet 0 75ft3 1 0ft3 1 5ft3 2 0ft3 3 0 ft3 Filter Tank Size 8x44 9x48 10x54 12x52 14x65 Tank Jacket Media Loaded Yes Yes Yes No No Shipping Weight 50lbs 60lbs 78lbs 95lbs 138 lbs Serv...

Page 5: ...ilitates the removal of iron and manganese by raising the pH This enables an iron filter to be used Periodic backwashing cleans the bed Addi tional media may be required six months to two years after...

Page 6: ...Put the filter in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for wa ter damage A 120 volt electric outlet to plug the in cluded transform...

Page 7: ...pump must be capable of providing the backwash flow rates indicated on page 4 Check Your Pumping Rate Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipm...

Page 8: ...when soldering pipes that are connected to the valve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also inclu...

Page 9: ...9 Filter Installation...

Page 10: ...locked press SETTINGS for 3 seconds to unlock Press and hold the MANUL REGEN Key for 3 seconds Press any key to skip the BRINE cycle 4 Open the inlet on the bypass valve slightly and very slowly allow...

Page 11: ...3 2 2 2 2 2 2 5 6 6 4 4 3 3 3 3 2 2 2 2 1 1 1 1 6 6 6 4 4 3 3 3 2 2 2 2 1 1 1 1 1 7 6 4 4 3 3 2 2 2 1 1 1 1 1 1 1 1 8 6 4 4 3 2 2 2 2 1 1 1 1 1 1 1 1 9 4 4 3 3 2 2 1 1 1 1 1 1 1 1 1 1 10 4 3 3 2 2 1 1...

Page 12: ...l through the diagnostics press the down or up key To reset the TOTAL REGENS TOTAL GALLONS OVER RUN TO TAL or PEAK flow rates press and hold the MENU until the value changes to zero PARAMETER DESCRIPT...

Page 13: ...to 30 minutes During this time you may hear water running intermittently to the drain Manual Bypass In the case of emergency you can isolate your water filter from the water supply using the bypass va...

Page 14: ...r to determine the expected life of your media bed AC Taste and Odor Filter under normal operating conditions the effective life of the filter media is approximately one to three years depending on th...

Page 15: ...2 Fine gravel 2 Fine gravel 3 Carbon 3 Calcite Once this is done the rag or cork should be removed from the distributor tube Clean off the top of the tank Finally place the control valve on the tank a...

Page 16: ...Main Repair Parts Replacing Drain Line Flow Control DLFC 1 Remove the red clip that secures the drain line elbow 2 Remove the BLFC washer from the elbow fitting 3 Reassemble using the reverse procedu...

Page 17: ...17 Filter Exploded View Brine tank for softener system only...

Page 18: ...18 A A A B D F E A C Main Repair Parts Connectors...

Page 19: ...TOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032 INJECTOR SET 2 BLUE 6001013...

Page 20: ...0 1 5056063 O Ring 78 74 5 33 A21 1 26010103 O Ring 25 3 55 A22 1 7060007 Valve Bottom Connector A23 1 13000426 Screw ST2 9X13 Large Washer A24 2 5031022 O Ring 32 3 A25 1 5031021 O Ring 18 3 A26 1 50...

Page 21: ...21 Power Head Exploded View...

Page 22: ...6 Screw ST2 9X13 Large Washer A24 2 5056139 Washer 3x13 B09 1 5030007 BNT85 Main Gear B10 1 5030005 BNT185 Housing B11 1 5031017 BNT85HE Brine Gear Downflow B12 1 5010023 Magnet 3 2 7 B13 1 5056141 Wa...

Page 23: ...23 Trouble Shooting...

Page 24: ...mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times operated in accordance with specifications and not...

Reviews: