Specifications 

Continuous operation at flow rates greater than the ser-
vice  flow  rate  may  affect  capacity  and  efficiency  per-
formance. 
The  manufacturer  reserves  the  right  to  make  product 
improvements which may deviate from the specifications 
and  descriptions  stated  herein,  without  obligation  to 

change previously manufactured products or to note the 
change. 

Peak  flow  rates  are  intended  for  intermittent  use  only 
and are for residential application only 
At  the  stated  service  flow  rates,  the  pressure  drop 
through these devices will not exceed 15 psig 

Service Flow Rates
          Normal

4.0 gpm

5.0 gpm

7.0 gpm

10.0 gpm

12.0 gpm

          Peak

5.0 gpm

7.0 gpm

10.0 gpm

12.0 gpm

15.0 gpm

Micron Rating

15­20 micron

15­20 micron

15­20 micron

15­20 micron

15­20 micron

Backwash Flow Rate

4.0 gpm

5.0 gpm

7.0 gpm

10.0 gpm

14.0 gpm

Filter Media Volume ­ Cubic Feet

0.75 ft

3

1.0 ft

3

1.5 ft

3

2.0 ft

3

3.0 ft

3

Filter Tank Size

8x44

9x48

10x54

12x52

14x65

Tank Jacket / Media Loaded

Yes

Yes

Yes

No

No

Shipping Weight

79 lbs

118 lbs

144 lbs

198 lbs

342 lbs

Service Flow Rates
          Normal

4.0 gpm

5.0 gpm

7.0 gpm

10 gpm

12.0 gpm

          Peak

5.0 gpm

7.0 gpm

10.0 gpm

12.0 gpm

15.0 gpm

Backwash Flow Rate

3.5 gpm

4.0 gpm

5.0 gpm

7.0 gpm

10.0 gpm

Filter Media Volume ­ Cubic Feet

0.75 ft

3

1.0 ft

3

1.5 ft

3

2.0 ft

3

3.0 ft

3

Filter Tank Size

8x44

9x48

10x54

12x52

14x65

Tank Jacket / Media Loaded

Yes

Yes

Yes

No

No

Shipping Weight

50 lbs

60 lbs

78 lbs

95 lbs

138 lbs

Service Flow Rates

          Normal

2.0 gpm

3.0 gpm

5.0 gpm

6.0 gpm

7.0 gpm

          Peak

3.5 gpm

5.0 gpm

8.0 gpm

10.0 gpm

12.0 gpm

Backwash Flow Rate

3.5 gpm

4.0 gpm

5.0 gpm

7.0 gpm

10.0 gpm

Filter Media Volume ­ Cubic Feet

0.75 ft

3

1.0 ft

3

1.5 ft

3

2.0 ft

3

3.0 ft

3

Filter Tank Size

8x44

9x48

10x54

12x52

14x65

Tank Jacket / Media Loaded

Yes

Yes

Yes

No

No

Shipping Weight

93 lbs

120 lbs

164 lbs

207 lbs

330 lbs

Service Flow Rates
          Normal

4.0 gpm

5.0 gpm

8.0 gpm

10.0 gpm

          Peak

7.0 gpm

8.0 gpm

10.0 gpm

12 gpm

Micron Rating

3­5 micron

3­5 micron

3­5 micron

3­5 micron

Backwash Flow Rate

5.0 gpm

7.0 gpm

10.0 gpm

14.0 gpm

Filter Media Volume ­ Cubic Feet

0.75 ft

3

1.0 ft

3

1.5 ft

3

2.0 ft

3

Filter Tank Size

8x44

9x48

10x54

12x52

Tank Jacket

Yes

Yes

Yes

No

Shipping Weight

90 lbs

135 lbs

205 lbs

255 lbs

ALL FILTERS
Plumbing Connections
Electrical Requirements
Water Temperature

Water Pressure

3/4" (Optional 1")

Input 120V 60 Hz ­ Output 12V 650mA

Min 39  ­ Max. 100 degrees Fahrenheit

Min. 20 ­ Max. 125 psi

48NEX-75

585NEX-100

585NEX-150

585NEX-200

485NU-75

585NU-100

585NU-150

585NU-200

585NU-300

585TO-75

585TO-100

585TO-150

585TO-200

585TO-300

585MM-75

585MM-100

585MM-150

585MM-200

585MM-300

Specifications

Specifications

Specifications

Specifications

Summary of Contents for 785

Page 1: ...ying provided with install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfectio...

Page 2: ...anual must be followed to minimize the risk of electric shock property damage or personal injury Be sure to check the entire unit for any shipping damage or parts loss Also note damage to the shipping...

Page 3: ...Excessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all gov erning codes and ordinances Use only lead free solder and flux for all sweat so...

Page 4: ...edia Volume Cubic Feet 0 75ft3 1 0ft3 1 5ft3 2 0ft3 3 0 ft3 Filter Tank Size 8x44 9x48 10x54 12x52 14x65 Tank Jacket Media Loaded Yes Yes Yes No No Shipping Weight 50lbs 60lbs 78lbs 95lbs 138 lbs Serv...

Page 5: ...ilitates the removal of iron and manganese by raising the pH This enables an iron filter to be used Periodic backwashing cleans the bed Addi tional media may be required six months to two years after...

Page 6: ...Put the filter in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for wa ter damage A 120 volt electric outlet to plug the in cluded transform...

Page 7: ...pump must be capable of providing the backwash flow rates indicated on page 4 Check Your Pumping Rate Two water system conditions must be checked carefully to avoid unsatisfactory operation or equipm...

Page 8: ...when soldering pipes that are connected to the valve Failure to do this could cause damage to the valve 5 Connect the drain hose 10 ft included to the valve and secure it with a hose clamp also inclu...

Page 9: ...9 Filter Installation...

Page 10: ...locked press SETTINGS for 3 seconds to unlock Press and hold the MANUL REGEN Key for 3 seconds Press any key to skip the BRINE cycle 4 Open the inlet on the bypass valve slightly and very slowly allow...

Page 11: ...3 2 2 2 2 2 2 5 6 6 4 4 3 3 3 3 2 2 2 2 1 1 1 1 6 6 6 4 4 3 3 3 2 2 2 2 1 1 1 1 1 7 6 4 4 3 3 2 2 2 1 1 1 1 1 1 1 1 8 6 4 4 3 2 2 2 2 1 1 1 1 1 1 1 1 9 4 4 3 3 2 2 1 1 1 1 1 1 1 1 1 1 10 4 3 3 2 2 1 1...

Page 12: ...l through the diagnostics press the down or up key To reset the TOTAL REGENS TOTAL GALLONS OVER RUN TO TAL or PEAK flow rates press and hold the MENU until the value changes to zero PARAMETER DESCRIPT...

Page 13: ...to 30 minutes During this time you may hear water running intermittently to the drain Manual Bypass In the case of emergency you can isolate your water filter from the water supply using the bypass va...

Page 14: ...r to determine the expected life of your media bed AC Taste and Odor Filter under normal operating conditions the effective life of the filter media is approximately one to three years depending on th...

Page 15: ...2 Fine gravel 2 Fine gravel 3 Carbon 3 Calcite Once this is done the rag or cork should be removed from the distributor tube Clean off the top of the tank Finally place the control valve on the tank a...

Page 16: ...Main Repair Parts Replacing Drain Line Flow Control DLFC 1 Remove the red clip that secures the drain line elbow 2 Remove the BLFC washer from the elbow fitting 3 Reassemble using the reverse procedu...

Page 17: ...17 Filter Exploded View Brine tank for softener system only...

Page 18: ...18 A A A B D F E A C Main Repair Parts Connectors...

Page 19: ...TOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032 INJECTOR SET 2 BLUE 6001013...

Page 20: ...0 1 5056063 O Ring 78 74 5 33 A21 1 26010103 O Ring 25 3 55 A22 1 7060007 Valve Bottom Connector A23 1 13000426 Screw ST2 9X13 Large Washer A24 2 5031022 O Ring 32 3 A25 1 5031021 O Ring 18 3 A26 1 50...

Page 21: ...21 Power Head Exploded View...

Page 22: ...6 Screw ST2 9X13 Large Washer A24 2 5056139 Washer 3x13 B09 1 5030007 BNT85 Main Gear B10 1 5030005 BNT185 Housing B11 1 5031017 BNT85HE Brine Gear Downflow B12 1 5010023 Magnet 3 2 7 B13 1 5056141 Wa...

Page 23: ...23 Trouble Shooting...

Page 24: ...mineral tank or brine tank to any original equipment purchaser in possession of a tank that fails provided that the water conditioner is at all times operated in accordance with specifications and not...

Reviews: