Aiming
Procedures
Horizontal line used as low beam
inspection upper limit.
Horizontal line used as low
beam inspection lower limit.
Biased line for the
European type low beam
Two vertical lines used as low
beam lateral inspection limits.
Illustrations on the following pages show more detail for specific types of lamps.
100 mm
100 mm
100
mm
100
mm
4"
4"
4"
0"
4"
8"
DESCRIPTION OF THE INTERNAL SCREEN OF THE AIMER
The Panther 5405 is designed to reproduce, at a smaller scale, an aiming test screen
compliant with the Standard SAE J599 (revised Aug. 1997). The beam projections appear
on the internal screen of the aimer as they would appear on a screen located 25 feet from
the headlamps.
The aiming screen complies with all aiming and inspection requirements of the Standards
SAE J599 (revised August 1997) and SAE J600 (revised February 1993).
With the lines drawn on the internal screen of the aimer, all aiming and testing procedures
can be performed
.
In addition, the European type lighting can also be aimed.
according to the inspection limits described in the Standards
Page 12 - Aiming Procedures - The Aiming Screen
Canbuilt Mfg.
Perfect Night Vision.....