background image

M U L T I - P U R P O S E   A P P L I C A T I O N   B O A R D S   F O R   D M S - 2 0 M E T E R S

DMS-EB2

MPM_DMS-EB2_D00 

 Page 2 of 4

D I G I T A L   P A N E L   M E T E R S

www.cd4power.com

TECHNICAL NOTES

APPLICATIONS

1.  LCD Backlighting:

 To backlight a DMS-20LCD meter, connect J1, pin 

3 (TEST/HOLD IN) to J1, pin 6 (GND).  This allows for external control, 
via a switch, of the backlight feature.  The switch should be rated for low 
voltage operation at 35mA.

2.  9V LCD Meters:

 DMS-20LCD-X-9 meters cannot be used in a single-

ended configuration, i.e., with (–) IN LO tied to GND.  On these models, 
both (–) IN LO and (+) IN HI have to be a minimum of 1.5V above and 
1.5V below J1 pins 6 and 5, respectively.  To operate from a 9V or 12V 
battery with (–) IN LO tied to GND, use a 5V-powered meter (DMS-
20LCD-X-5), install U1 (LM7805CT) and open SG4.

3.  Input Resistor Dividers:

 Always use 1%, or better, metal-film resistors 

for R1 and R2, and also make sure their power and voltage ratings are 
adequate for the given application.

4.  Using U1 (LM7805CT):

 The input power range specified in the Battery 

Operation section is rated conservatively assuming a 100mA LED meter 
or a 35mA backlit LCD meter.  If a non-backlit LCD model or the low-
power LED model is used, the input voltage range can be extended up to 
32Vdc.

As shipped, the DMS-EB2 is configured for single-ended operation.  This 
configuration is preferred for simple voltage measurements and will gen-
erally cover most standard applications.  Figure 1 indicates which solder 
gaps are shipped closed from the factory.
Simply solder the board onto the meter (pin 1 to pin 1), connect the power 
supply to J1, pin 5 (+V) and the power return to J1, pin 6 (GROUND).

1.  Decimal Point Placement:

 DATEL ships the DMS-EB2 with all decimal 

point solder gaps (SG1, SG2 and SG3) open.  To enable a specific deci-
mal point, close its respective solder gap with solder.  When re-assigning 
decimal places for subsequent applications, remember to unsolder previ-
ously closed solder gaps.

  Close SG1 for 1.999 (DP1) 

 Close SG2 for 19.99 (DP2) 
 Close SG3 for 199.9 (DP3)

2.  Display Test 

(Not Available on LCD Models)

:

 Tie pin 4 (TEST/HOLD 

OUT) to pin 3 (TEST/HOLD IN) to test the display of the DMS-20PC.  Do 
not leave the meter in the test mode for more than 10 seconds.  On LED 
meters with the HOLD option, tying pins 3 and 4 together freezes the 
display reading.

3.  Battery Operation: 

Open SG4 and install U1 (LM7805CT) with its metal 

tab facing to the left as shown in Figure 3. Allowable input power ranges 
(J1,  pins 5 and 6) are as follows:

   DMS-20PC-X-XS  +7.5 to +12.6Vdc 

 DMS-20PC-X-XL  +7.5 to +32Vdc

  C2 (10µF/35V) can be added to reduce noise.  Observe correct polarity.  

Refer to Technical Note 4 for more information.

Figure 2. J1 Connector Pinout

  Pin  Function
  1  (+) INPUT HI
  2  (–) INPUT LO
  3  TEST/HOLD IN
  4  TEST/HOLD OUT
  5  +V (Positive power connection)

  6  –V (Ground, negative power return)

1

2

3

4

5

6

+V

HI�

(+)

LO�

(–)

TST/�

HOLD�

IN

TST/�

HOLD�

OUT

–V�

GND

J1

  DMS-EB2

 

Application board with mating connector and terminals

  DMS-BZL3

 

DMS-20 bezel assembly

 

DMS-BZL4

 

DMS-20 bezel assembly with sealing gasket

 

39-0304000

 

LM7805CT (U1), +5V-output, three-terminal regulator

 

39-2359625

 

6-position pc-board socket

Input Supply Range

  

  See applicable meter's data sheet

Input Supply Range U1 (LM7805CT) Installed:

  DMS-20PC-X-XS 

+7.5 to +12.6V 

  DMS-20PC-X-XL 

+7.5 to +32.0V 

  DMS-20LCD-X-5 

+7.5 to +32.0V 

  DMS-20LCD-X-5B           

+7.5 to +12.6V

Operating and Storage Temperature

 

  See applicable meter's data sheet

Humidity

 

0 to 95%, non-condensing

Dimensions

 

1.25" (31.8mm)L x 0.75" (19.1mm)H

J1 Connector & Wire Information

  Terminal Type 

DATEL P/N 39-2099090 

  Crimp Tool 

DATEL P/N 39-2099000 

  Wire Size 

22 to 26 AWG 

  Insulation Diameter 

0.062" (1.57mm) max. 

  Stripping Length 

0.100" to 0.125"   

   

(2.54 to 3.17mm)

Ordering Information

Functional Specifications  (T

A

 = 25ºC)

  A 10µF/35V tantalum capacitor (C2 on schematic) should be installed 

with the polarized end next to the + symbol on the DMS-EB2. This is 
especially important if the power source is located far from U1.

5.  Soldering: 

DATEL recommends the use of "no-clean" solders when 

making modifications to the DMS-EB2.