Systems
Systems
Ventilation system
The ventilation system ensures that both components and cabin are kept fresh and dry and
that any odors or gases are removed.
The cabin has a fresh air intake through ducts under the dashboard and in the cabin ceiling.
Hot air is released through the lower ducts, inside the cabin, and through the dashboard
ducts, to prevent condensation on the windshield.
The optional holding tanks for freshwater and black water, are ventilated through a dashboard
vent and through the anchor box. An odor from the anchor box might indicate that a change
of odor filter is necessary.
The bilge pumps and battery are naturally ventilated through the sunbed and hull,
respectively.
NOTICE! Keep all ducts free from blockage. This will maintain a well-functioning
ventilation system and prevent odor.
D
A
H
I
I
B
H
B
F
G
E
E
E
C
F
F C
G
G
B
C
A.
Cabin fresh air system
B.
Fresh air duct from
dashboard x2
C.
Fresh air duct cabin x2
D.
Hot air system
E.
Hot air ducts wind-
shield x2
F.
Hot air dampers x2
G.
Hot air ducts cabin x2
H.
Freshwater tank
ventilation duct
(behind the dash-
board)
I.
Black water tank
ventilation duct
(anchor box)
Heating the cabin
1. In the Outputs settings in the user interface, activate the Cabin heater.
2. Pull the hot-air damper(s) in the cabin.
3. Hot air is released from the hot air ducts.
A
A
B
B
2x
2x
A
B
Defogging the windshield
1. In the Outputs settings in the user interface, activate the Defogger.
2. Push the hot air damper(s) in the cabin.
3. Hot air is released to the windshield from the ducts on the dashboard.
A
A
2x
A
B
B
B
A.
Hot air damper x2
B.
Hot air ducts windshield x2
A.
Hot air damper x2
B.
Hot air ducts cabin x2