2
1.2
FEATURES AND SPECIFICATIONS
1.2.1
Key Features
Supports eight ANSI/VITA 12-1996 compliant single-wide M or MA-modules or a
combination of double or triple-wide modules
Complies with LXI Standard Rev. 1.1 for a Class C (Bridge) instrument
Ethernet 10Base-T, 100Base-TX (Auto-Sensing)
Rugged steel/aluminum 19 inch rack mount 1U High enclosure
AC Input 85-265VAC, 47-63Hz (accepts standard IEC 320-C13 power cords)
Alternatively powered by an ex48VDC (5-pin circular DIN connector)
Forced air cooling with software temperature status monitoring
IVI driver provides control of the EM405-8 bridge functions
Configuration through an intuitive web interface
Flexible block access command provides rapid sequential and FIFO data accesses
External and inter-module triggers supported (-0001 version only)*
Isolated and fi5V, +12V, and -12V supplies for each M-Module
Power-off reset-able breakers provided for each M-Module position
* The triggers have currently not been approved as LXI compliant. Use should be
limited to non-LXI applications.
1.2.2
Specifications
MAXIMUM RATINGS
Parameter
Condition
Rating
Units
Operating Temperature
0 to +60
C
Non-Operating Temperature
-40 to +75
C
Humidity
non-condensing
5 to 95
%
DC Input Voltage Level
75
V max.
DC Input Surge Voltage
100ms
100
V max.
AC Input Protection
rocker switch
4
A max.
Input Power Consumption
with 8 M-Modules at 10W each
100
Watts
Total M-Module Current (total for all
eight positions)
+5V
+12V
-12V
8.0
1.6
1.6
A
A
A
M-Module Current (each position,
total for all M-Modules can not
exceed Total M-Module Current)
+5V
+12V
-12V
2.0
900
900
A
mA
mA
External TTL Trigger Input
(-0001 versions only)
Power Off
Power On
± 40
± 36
V
V
C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, Texas 78681 <> www.chtech.com