background image

 

 

11 

4.0

 

OPERATION 

 
The  M222  is  a  register-based  instrument  that  is  controlled  through  a  series  of  I/O  registers 
described  in  Section  3.2.1.    The  exact  method  of  accessing  and  addressing  the  I/O  registers  is 
dependent on the M-Module carrier used to interface the module to your data acquisition or test 
system.    Refer  to  the  carrier’s  documentation  for  information  on  the  address mapping of an M-
Module’s I/O registers and to your system software documentation for details on data access. 
 
Typically  a  high  level  driver  is  available  to  aid  in  control  of  the  module.    Refer  to  the  software 
driver documentation for instructions on using the driver. 
 
4.1

 

RELAY OPEN/CLOSE 

 
Each relay channel can be separately controlled with the Relay Register (Reg. 0x14).  Writing a 1 
to a bit will OPEN the relay (i.e., connect the common terminal to the normally closed terminal) 
and writing a 0 to a bit will CLOSE the relay (i.e., connect the common terminal to the normally 
open terminal) as shown in Figure 4. 
 

 

Figure 4.  Effects of Opening/Closing Relay 

 

 

4.2

 

INTERRUPTS 

 
The M222 can generate an interrupt request 16ms after a relay is opened or closed indicating that 
the relay has settled.  The interrupt must be enabled in the Control Register (Reg. 0x02). 
 
M-module  carriers  and  system  controllers  treat  the  interrupts  differently.    Refer  to  your  carrier 
and  controller  documentation  to  determine  how  to  properly  configure  them  to  handle  the  M-
module interrupt request. 

C&H Technologies, Inc. <> 445 Round Rock West Drive <> Round Rock, TX 78681 <> www.chtech.com

Summary of Contents for M222

Page 1: ...O R M E R L Y H P E 2 2 7 4 A U S E R S M A N U A L 4 C H A N N E L F O R M C P O W E R R E L A Y M M O D U L E Document Part No 11029574 C H Technologies Inc 445 Round Rock West Drive Round Rock TX 7...

Page 2: ...t Hewlett Packard Agilent User Manual s with their expressed written permission The information and or drawings set forth in this document and all rights in and to inventions disclosed herein which mi...

Page 3: ...amendments to the manual If any amendments are provided for this manual they are printed on colored paper and will be provided with the module and manual Manual updates may also be found on out web s...

Page 4: ...are available in many formats such as Ethernet VME VXI PXI cPCI and the PC Contained within this manual are the physical and electrical specifications installation and startup procedures functional de...

Page 5: ...PECTION 5 2 2 HANDLING PRECAUTIONS 5 2 3 INSTALLATION OF M MA MODULES 5 2 4 PREPARATION FOR RESHIPMENT 6 3 0 FUNCTIONAL DESCRIPTION 7 3 1 OVERVIEW 7 3 1 1 M Module Interface 7 3 1 2 ID EEPROM 7 3 2 ID...

Page 6: ...isters 9 Figure 4 Effects of Opening Closing Relay 11 Figure A 1 Front Panel I O Signals A 1 LIST OF TABLES Table I Specifications 2 Table II I O Address Map Command Summary 8 Table III M MA Module PR...

Page 7: ...her system architectures 1 1 PURPOSE OF EQUIPMENT The M222 can connect multiple instruments to multiple points in your test system This provides flexible interconnection between test points instrument...

Page 8: ...on Clean room Environment any terminal to any other terminal 60 43 68 VDC VAC rms VAC peak Current non inductive Per Switch DC Per Switch AC Per Switch AC 5 3 53 5 A A rms A peak Power Per Switch DC P...

Page 9: ...MA not supported Triggers not supported Identification IDENT Manufacturer ID 0FFF16 See note below Model Number 068A16 VXI Model Number 025F16 Note C H obtained the manufacturing rights from Hewlett P...

Page 10: ...4 C H Technologies Inc 445 Round Rock West Drive Round Rock TX 78681 www chtech com...

Page 11: ...a static controlled workstation whenever possible At a minimum avoid work areas that are potential static sources such as carpeted areas Avoid unnecessary contact with the components on the module 2 3...

Page 12: ...ealing the bag keep trapped air volume to a minimum The shipping container should be a rigid box of sufficient size and strength to protect the equipment from damage If the module was received separat...

Page 13: ...ows communication between the M222 and the carrier module The interface is an asynchronous 16 bit data bus with interrupt capabilities The interface adheres to the ANSI VITA 12 1996 Standard for The M...

Page 14: ...the registers is shown in Table II Details of the registers are provided in Figure 3 Table II I O Address Map Command Summary Offset hex Register Name Register Type 00 Status Register Read Only 02 Con...

Page 15: ...ing this register clears a pending interrupt Reg 14 Relay Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Write Not Used CH3 CH2 CH1 CH0 Read Not Used CH3 CH2 CH1 CH0 CH0 CH3 Channel 1 channel open COM NC 0...

Page 16: ...Revision Number 1 0002 3 Module Characteristics 2 1868 4 7 Reserved 0000 8 15 M Module Specific 0000 16 VXI Sync Code ACBA 17 VXI ID 0FFF 3 18 VXI Device Type 3 F25F 19 31 Reserved 0000 32 63 M Module...

Page 17: ...CLOSE Each relay channel can be separately controlled with the Relay Register Reg 0x14 Writing a 1 to a bit will OPEN the relay i e connect the common terminal to the normally closed terminal and writ...

Page 18: ...12 C H Technologies Inc 445 Round Rock West Drive Round Rock TX 78681 www chtech com...

Page 19: ...ctive that may be applied to the M222 is Per Switch 5 ADC 5 AAC peak 100W DC 100VA AC Per Module 300W DC 300VA AC Pin Use Pin Use Pin Use 1 CH0_NC 16 CH0_NC 31 CH0_NC 2 CH0_COM 17 CH0_COM 32 CH0_COM 3...

Page 20: ...A 2 C H Technologies Inc 445 Round Rock West Drive Round Rock TX 78681 www chtech com...

Page 21: ...N O T E S C H Technologies Inc 445 Round Rock West Drive Round Rock TX 78681 www chtech com...

Page 22: ...C H Technologies Inc 445 Round Rock West Drive Round Rock TX 78681 www chtech com...

Page 23: ...tsoever You may of course continue to use the information which you supply Please refrain from using this form for technical questions or for requests for additional publications this will only delay...

Page 24: ...her or not your comments were being incorporated NOTE This form may not be used to request copies of documents or to request waivers deviations or clarification of specification requirements on curren...

Reviews: