SUPERVISION 

All of your individual wireless detectors (PIR's, Reeds or Smoke Detectors) can send a supervision report to your 236i - 
WRX receiver to confirm that they are fully functional.  
 
If you have purchased the 236i Kit, supervision has already been enabled for each detector programmed in at the factory.  
NOTE: If you remove a detector, you must disable the supervision report for that channel, otherwise the fault output will be 
activated as detailed below. 
 
If supervision mode is enabled for a particular channel, the receiver will be expecting to receive the supervision code from 
the detector learnt into that respective channel every 2.4 hours i.e. at least 10 reports per day, per detector.  
 
The 236i - WRX only requires one report from each detector during the 24 hour period to satisfy the supervision criteria. An 
extra 9 reports are still given to ensure that the supervision report is received.  
 
If all 10 supervision reports are missed from one detector during the 24 hour time frame, then the fault output will be 
activated (it will switch low for 2 seconds). 
 

TURNING SUPERVISION REPORTS ON OR OFF FOR CHANNELS 2 - 6 

(Zones 1 - 5) 

 

1.  Enter programming mode. 
2.  Select Channel 12. 
 
 
3.  Via FEATURE MODE lights, press the GREEN Button to select the desired Channel / Zone that you wish to enable or 

disable supervision for as shown in diagram below.  

 
 
 
 
 
 

 

FLASHING MODE LIGHTS indicate supervision is OFF for that Channel / Zone. 

 

MODE LIGHTS ON indicate supervision is ON for that Channel / Zone. 

 
4.  Select first the lowest Channel / Zone that you wish to change the supervision setting for, press the RED button on your 

remote to toggle the LED lights from ON to Flashing, depending on whether you wish to enable or disable supervision 
for that Channel / Zone. 

5.  Press the green button to move to the next channel as per Step 3, if there is another Channel / Zone that you wish to 

enable / disable supervision. NOTE: Once you have passed Channel 7, you will not automatically loop back to Channel 
2 / Zone 1. You must exit supervision programming & restart procedure. 

6.  To exit supervision programming mode, hold down the GREEN button until the LED’s begin to scroll again (approx. 5 

sec).  

 

LOW BATTERY & TAMPER WARNING 

 

CHANNEL 12

8

4

2

1

Channe1 2 / Zone 1 

4

2

1

Channel 4 / Zone 3

4

2

1

Channel 5 / Zone 4 

4

2

1

Channel 3 / Zone 2 

4

2

1

Channel 6 / Zone 5

4

2

1

 

Your detectors will automatically transmit a low battery report to your 236i - WRX receiver when the batteries are nearly 
flat.  

 

The low battery report code is transmitted every time a detector sends a supervision report, or whenever the detector is 
triggered.  

 

6

Summary of Contents for 236i-WRX

Page 1: ...4 6 Wireless PIR Output Zone 3 5 Wireless PIR Output Zone 2 4 Wireless PIR Output Zone 1 3 Keypad Data Output Connect to DATA 2 Connect to C 1 Connect to KEY Antenna Wire Do Not Cut Optimum operation...

Page 2: ...6 and push the key 1 3 Enter the 4 digit 236I WRX User Pin Number located on the white sticker near the connector on the receiver module and then push the key 4 Enter the new PIN again and push the ke...

Page 3: ...PROGRAMMING MODE 1 Press keep holding down the green left button until the LED lights begin to scroll again approx 5 seconds SELECTING THE CHANNEL YOU WISH TO PROGRAM IMPORTANT When programming make s...

Page 4: ...mote control on off 4 times in quick succession E Channel 1 light will stop flashing to confirm that the remote has been successfully learnt F To exit programming mode hold down the GREEN button until...

Page 5: ...amming mode again Learning a new detector into a channel which already had a detector learnt into that channel will erase the original detector code replace it with the new detector s code After learn...

Page 6: ...TURE MODE lights press the GREEN Button to select the desired Channel Zone that you wish to enable or disable supervision for as shown in diagram below FLASHING MODE LIGHTS indicate supervision is OFF...

Page 7: ...ill switch low for 2 seconds to indicate that the detector has a flat battery The tamper output will switch low for 2 seconds whenever the front case is removed and the tamper switch is released on a...

Reviews: