ENTRY CIRCUIT

Starts the entry timer when activated providing the panel is set.

FIRE 

(for use with smoke detectors)

A zone that when activated emits an ascending sound from any internal

speakers. If the panel is set, external sirens and strobes also sound, but in

an unset state the external sounders pulse every two seconds.

TAMPER

A loop that should run through every device on your system. If broken, it

triggers the internal speakers. If the panel is set, external sounders and

strobes also trigger. The tamper LED appears on the keypad as 

TPR.

CHIME

Chime is similar to a doorbell. This can be used to alert a user to a certain

zone being triggered during the day.

DOOR SENSE SETTING

Allows you to have a variable FULL SET EXIT TIME. You can program the

EXIT time to maximum, and when you FULL SET the system, the exit time

drops to 8 seconds as soon as the EXIT door has closed, thus avoiding the

preset exit time.

FULL SET KEYSWITCH

Allows the panel to be set, unset and reset through zone 8.

Note. 

 The keyswitch should be a spring loaded momentary type.  To use

the keyswitch for setting, unsetting and so on, connect across zone 8 and

program that zone to be KEYSWITCH. To SET the panel, turn the key so the

contacts are open. Hold in this position for about a second for full set or

about 2 seconds for NIGHT SET. To UNSET the panel, turn and hold for

about ½ second. To Reset you must open and close the KEYSWITCH after

an alarm condition.

THE ACCEPT TONE

Heard when an action is accepted.

THE ERROR TONE

Heard when an action is not accepted.

SERIES AND PARALLEL

GLOSSARY OF

TERMS

LATCHING DETECTORS

These detectors, when triggered during a set period, latch on to aid the

process of alarm event origin checking. Use these detectors if many detec-

tors are to be used on a single zone but are to cover a large area of space.

Summary of Contents for SECURIT ST800L+

Page 1: ...INSTALLATION MANUAL SECURIT 800L CONTROL PANEL ST800L...

Page 2: ...mote Keypad 7 POWERING UP 7 Initial Power Up 7 PROGRAMMING 8 Exit Time 8 Entry Time 8 Sounder Duration 9 Night Set Home Set Exit Time 9 Circuit Programming 10 Extended Programming Options 10 Home Set...

Page 3: ...e the unit will be repaired and returned free of charge PRODUCT DESCRIPTION The Securit 800L is an 8 zone programmable microprocessor control panel using state of the art technology and manufacturing...

Page 4: ...eight 2 7 kg Excluding Battery Stand by Battery 7 0Ahr max valnve regulated lead acid Standby Time load dependent 24 hrs with 2 8Ahr nom 60 hrs with 7 0Ahr nom based on panel keypad 2 PIR 40 20 25 25m...

Page 5: ...corrected by a qualified electrician to ensure continued safe operation CAUTION Under certain circumstances the transformer metalwork can reach 70 C This is normal and well within prescribed limits B...

Page 6: ...hat the sounder trigger is applied negative Negative ring ST Strobe switched negative trigger S Sounder switched negative trigger Sounder hold off strobe positive supply Sounder hold off supply sounde...

Page 7: ...MUST wire in series See the Glossary for series and parallel examples POWERING UP INITIAL POWER UP Note Keep the lid off the main control panel in order to enter engineer mode Alternatively you can e...

Page 8: ...e lid of the panel or keypad PROGRAMMING Once the panel is in engineering mode the following options are available EXIT TIME 3 0 Range 10 90 seconds Enter 3 0 The factory default is 30 seconds You can...

Page 9: ...he selection The accept tone then sounds Note If extension speakers are fitted in Night and Home set you can alter the exit sounder volume by the control on the PCB marked VOLUME Option Option Results...

Page 10: ...ULL SET Turn and hold for 2 0 seconds PART SET EXTENDED PROGRAMMING OPTIONS 7 Range 1 8 The control panel offers the following additional options Enter 7 1 Disables sounder and strobe in Night Set Ent...

Page 11: ...subsequent alarms as well as isolated circuits First to alarm is shown by the LED being ON continuously Subsequent alarms are shown by the LED s flashing and isolated circuits are shown by LED s puls...

Page 12: ...code to prevent unauthorised alteration To enable this the engineer code must end in 9 If the engineer code is lost it will not be possible to enter engineer mode the PCB will need to be replaced Thi...

Page 13: ...m the exit time drops to 8 seconds as soon as the EXIT door has closed thus avoiding the preset exit time FULL SET KEYSWITCH Allows the panel to be set unset and reset through zone 8 Note The keyswitc...

Page 14: ...RY VOLTAGE V AUX VOLTAGE V INSTALLED BY SOUNDER CONNECTIONS CONTROL PANEL ST S R SONADE 2000 STROBE B D A T FLASHGUARD XL STROBE SIREN SUPPLY SUPPLY TAMPER OUT STARLIGHT 2000 ST R H H RTN ACTIVEGUARD...

Page 15: ...ne activates even in day mode Programmed to PA or FIRE Reprogram the zone to be an alarm zone or similar If you are still experiencing problems then contact our technical helpline with information at...

Page 16: ...STEMS is always endeavouring to improve quality and specification of all its products and may alter or amend this product and instructions without notice C K Systems Ltd Unit 24 Walkers Road North Moo...

Reviews: