9

SOUNDER DURATION 3-2 (Range 3-20 minutes)

Enter 

3-2

. The factory default is 15 minutes.  You can program a new time by

entering one key from the following table.

Enter 1

 3  minutes. LED 1 on.

Enter 2

 4  minutes. LED 2 on.

Enter 3

 5  minutes. LED 3 on.

Enter 4

10 minutes. LED 4 on.

Enter 5

15 minutes. LED 5 on. (default)

Enter 6

20 minutes. LED 6 on.

Press 

*

 to confirm the selection. The accept tone then sounds.

NIGHT SET/HOME SET EXIT TIME 3-3 (Range 0-90 seconds)

Enter 

3-3

. The factory default is 15 seconds.  You can program a new time

by entering one key from the following table.

Enter 0

  0 Seconds. All LEDs off (Instant).

Enter 1

10 Seconds. LED 1 on.

Enter 2

15 Seconds. LED 2 on. (default)

Enter 3

30 Seconds. LED 3 on.

Enter 4

45 Seconds. LED 4 on.

Enter 5

60 Seconds. LED 5 on.

Enter 6

90 Seconds. LED 6 on.

Press 

*

 to confirm the selection. The accept tone then sounds.

Note

: If extension speakers are fitted in Night and Home set, you can alter

the exit sounder volume by the control on the PCB marked 

VOLUME

.

Option

Option

Results from choosing option no.

Code

Description

0

1

2

3

4

5

6

3-0

Exit Time (secs)

10

15

30

45

60

90

3-1

Entry Time (secs)

10

15

30

45

60

90

3-2

Sounder Duration (mins)

3

4

5

10

15

20

3-3

Night    /  Home  Exit  (secs)

0

10

15

30

45

60

90

After you enter the user code, the sounder starts at the lower controlled

volume. The volume increases after 5 seconds if Night or Home set are not

selected.

Examples

Change the full set Exit Time to 60 seconds

ENTER THIS

3-0

5

*

Description

Choose Full Set

Select 60 seconds

Confirm selection

Change the Sounder Duration to 3 minutes

ENTER THIS

3-2

1

*

Description

Choose Sounder

Select 3 minutes

Confirm selection

Change the Entry Time to 45 seconds

ENTER THIS

3-1

4

*

Description

Choose Entry

Select 45 seconds

Confirm selection

SUMMARY

NIGHT/HOME

SET EXIT

TIMER

SOUNDER

DURATION

Summary of Contents for SECURIT ST800L+

Page 1: ...INSTALLATION MANUAL SECURIT 800L CONTROL PANEL ST800L...

Page 2: ...mote Keypad 7 POWERING UP 7 Initial Power Up 7 PROGRAMMING 8 Exit Time 8 Entry Time 8 Sounder Duration 9 Night Set Home Set Exit Time 9 Circuit Programming 10 Extended Programming Options 10 Home Set...

Page 3: ...e the unit will be repaired and returned free of charge PRODUCT DESCRIPTION The Securit 800L is an 8 zone programmable microprocessor control panel using state of the art technology and manufacturing...

Page 4: ...eight 2 7 kg Excluding Battery Stand by Battery 7 0Ahr max valnve regulated lead acid Standby Time load dependent 24 hrs with 2 8Ahr nom 60 hrs with 7 0Ahr nom based on panel keypad 2 PIR 40 20 25 25m...

Page 5: ...corrected by a qualified electrician to ensure continued safe operation CAUTION Under certain circumstances the transformer metalwork can reach 70 C This is normal and well within prescribed limits B...

Page 6: ...hat the sounder trigger is applied negative Negative ring ST Strobe switched negative trigger S Sounder switched negative trigger Sounder hold off strobe positive supply Sounder hold off supply sounde...

Page 7: ...MUST wire in series See the Glossary for series and parallel examples POWERING UP INITIAL POWER UP Note Keep the lid off the main control panel in order to enter engineer mode Alternatively you can e...

Page 8: ...e lid of the panel or keypad PROGRAMMING Once the panel is in engineering mode the following options are available EXIT TIME 3 0 Range 10 90 seconds Enter 3 0 The factory default is 30 seconds You can...

Page 9: ...he selection The accept tone then sounds Note If extension speakers are fitted in Night and Home set you can alter the exit sounder volume by the control on the PCB marked VOLUME Option Option Results...

Page 10: ...ULL SET Turn and hold for 2 0 seconds PART SET EXTENDED PROGRAMMING OPTIONS 7 Range 1 8 The control panel offers the following additional options Enter 7 1 Disables sounder and strobe in Night Set Ent...

Page 11: ...subsequent alarms as well as isolated circuits First to alarm is shown by the LED being ON continuously Subsequent alarms are shown by the LED s flashing and isolated circuits are shown by LED s puls...

Page 12: ...code to prevent unauthorised alteration To enable this the engineer code must end in 9 If the engineer code is lost it will not be possible to enter engineer mode the PCB will need to be replaced Thi...

Page 13: ...m the exit time drops to 8 seconds as soon as the EXIT door has closed thus avoiding the preset exit time FULL SET KEYSWITCH Allows the panel to be set unset and reset through zone 8 Note The keyswitc...

Page 14: ...RY VOLTAGE V AUX VOLTAGE V INSTALLED BY SOUNDER CONNECTIONS CONTROL PANEL ST S R SONADE 2000 STROBE B D A T FLASHGUARD XL STROBE SIREN SUPPLY SUPPLY TAMPER OUT STARLIGHT 2000 ST R H H RTN ACTIVEGUARD...

Page 15: ...ne activates even in day mode Programmed to PA or FIRE Reprogram the zone to be an alarm zone or similar If you are still experiencing problems then contact our technical helpline with information at...

Page 16: ...STEMS is always endeavouring to improve quality and specification of all its products and may alter or amend this product and instructions without notice C K Systems Ltd Unit 24 Walkers Road North Moo...

Reviews: