GENERAL
Carefully read the following important information regarding
installation safety and maintenance. Keep this information
booklet accessible for further consultations.
The appliance has been designed for use in the ducting
version (air exhaust to the outside – Fig.1B), filtering version
(air circulation on the inside – Fig.1A) or with external motor
(Fig.1C).
SAFETY PRECAUTION
1.
Take care when the cooker hood is operating simultaneously
with an open fireplace or burner that depend on the air in the
environment and are supplied by other than electrical energy,
as the cooker hood removes the air from the environment
which a burner or fireplace need for combustion. The negative
pressure in the environment must not exceed 4Pa (4x10-5 bar).
Provide adequate ventilation in the environment for a safe
operation of the cooker hood. Follow the local laws applicable
for external air evacuation.
Before connecting the model to the electricity network:
- control the data plate (positioned inside the appliance)
to ascertain that the voltage and power correspond to the
network and the socket is suitable. If in doubt ask a qualifi ed
electrician.
- If the power supply cable is damaged, it must be replaced
with another cable or a special assembly, which may be
obtained direct from the manufacturer or from the Technical
Assistance Centre.
- This device must be connected to the supply network
through either a plug
fused 3A
or hardwired to a 2 fase spur
protected by
3A fuse.
2. Warning !
In certain circumstances electrical appliances may be a
danger hazard.
A) Do not check the status of the fi lters while the cooker
hood is operating
B) Do not touch bulbs or adjacent areas, during or straight
after prolonged use of the lighting installation.
C) Flambè cooking is prohibited underneath the cooker
hood
D) Avoid free fl ame, as it is damaging for the fi lters and
a fi re hazard
E) Constantly check food frying to avoid that the
overheated oil may become a fi re hazard
F) Disconnec t the elec trical plug prior to any
maintenance.
G) This appliance is not intended for use by young
children or infi rm persons without supervision
H) Young children should be supervised to ensure they
do not play with the appliance
I) There shall be adequate ventilation of the room when
the rangehood is used at the same time as appliances
burning gas or other fuels
L) There is a risk of fi re if cleaning is not carried out in
accordance with the instructions
This appliance conforms to the European Directive EC/2002/96,
Waste Electrical and Electronic Equipment (WEEE). By making
sure that this appliance is disposed of in a suitable manner,
the user is helping to prevent potential damage to the
environment or to public health.
The
symbol on the product or on the accompanying
paperwork indicates that the appliance should not be treated
as domestic waste, but should be delivered to a suitable
electric and electronic appliance recycling collection point.
Follow local guidelines when disposing of waste. For more
information on the treatment, re-use and recycling of this
product, please contact your local authority, domestic waste
collection service or the shop where the appliance was
purchased.
INSTALLATION INSTRUCTIONS
Assembly and electrical connections must be carried out by
specialised personnel.
• Electric Connection
The appliance has been manufactured as a class II, therefore
no earth cable is necessary.
The connection to the mains is carried out as follows:
BROWN =
L
line
BLUE =
N
neutral
If not provided, connect a plug for the electrical load
indicated on the description label. Where a plug is provided,
the cooker hood must be installed in order that the plug is
easily accessible.
An omnipolar switch with a minimum opening of 3mm
between contacts, in line with the electrical load and local
standards, must be placed between the appliance and the
network in the case of direct connection to the electrical
network.
•
The minimum distance between the support surfaces of
the cooking pots on the cooker top and the lowest part of
the cooker hood must be at least 65 cm.
If a connection tube composed of two parts is used, the upper
part must be placed outside the lower part.
Do not connect the cooker hood exhaust to the same
conductor used to circulate hot air or for evacuating fumes
from other appliances generated by other than an electrical
source. In the case of assembly of the appliance in the suction
version prepare the hole for evacuation of the air.
•
We recommend the use of an air exhaust tube which has
the same diameter as the air exhaust outlet hole. If a pipe
with a smaller diameter is used, the efficiency of the product
may be reduced and its operation may become noisier.
• Warning:
if the bulbs are not working, ensure that they are
screwed in fully.
•
Installation
Prior to proceeding with the assembly operations (according
to the model that you have purchased), to facilitate handling
of the device, remove the grille as indicated in fi gure 6.
•
Fitting the front panel
To make fixing the front panel in place easier, the cooker
hood flap may be removed in the following manner:
ENGLISH