Electrical Installation 

All installation must be carried out by a competent person or qualified electrician. 
Before connecting the mains supply ensure that the mains voltage corresponds to the 
voltage on the rating plate.  
 
Direct Connection 
The appliance must be connected directly to the mains using an omnipolar circuit 
breaker with a  
minimum opening of 3mm between the contacts. 
The installer must ensure that the correct electrical connection has been made and 
that it complies with the wiring diagram. 
The cable must not be bent or compressed. 
Regularly check the power plug and power cord for damage. If the supply 
cord is damaged, it must be replaced by a special cord or assembly 
available from the manufacturer or its service agent. 
 
This appliance is supplied with a 2 core mains cable coloured as follows: 
Brown = L or Live     
Blue = N or Neutral     
 

WARNING: 

 

 

For safety reason, use only the same size of 
fixing or mounting screws which are 
recommended in this instruction manual. 

 

Failure to install the screws or fixing device in 
accordance with these instructions may result in 
electrical hazards.

 

Summary of Contents for CFT611NS/S

Page 1: ...1 CFT611NS S Cooker Hood Instruction Manual ...

Page 2: ...2 Content Safety instructions 3 Installation 5 Start using your cooker hood 8 Troubleshooting 8 Maintenance and cleaning 9 Environment protection 12 ...

Page 3: ...oker hood is located above a gas appliance this distance shall be at least 65 cm The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels Always to do Important Always switch off the electricity supply at the mains during installation and maintenance such as light bulb replacement The cooker hood must be installed in accordance with th...

Page 4: ...s Children younger than 8 years old should stay away unless they are under permanent supervision There shall be adequate ventilation of the room when the cooker hood is used at the same time as appliances burning gas or other fuels There is a fire risk if cleaning is not carried out in accordance with the instructions Regulations concerning the discharge of air have to be fulfilled Clean your appl...

Page 5: ...8mm at a suitable place according to the centre distance of the holes in the back of the cooker hood See Pic 2 3 Insert the wall plugs into the holes 4 Insert the ST4 30mm screws into the wall plugs and tighten 5 Put up the cooker hood onto the fixed screws 6 Use the attached accessories enclosed to turn the safety screws into the two holes inside the hood and then fix the screws to tighten the ho...

Page 6: ...d when installing Horizontal ventilation See Pic 5 A please use a tool to knock out the outlet cover on the top then the air can be vented from the top Vertical ventilation See Pic 5 B please use a tool to knock out the outlet cover on the back then the air can be vented from the back Air ventilation setting Outdoor air ventilation Turn the adjuster to the outdoor position pic 6A install the outle...

Page 7: ...nnection has been made and that it complies with the wiring diagram The cable must not be bent or compressed Regularly check the power plug and power cord for damage If the supply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer or its service agent This appliance is supplied with a 2 core mains cable coloured as follows Brown L or Live Blue N or Ne...

Page 8: ...ower outlet Switch power outlet on Oil leakage One way valve and the outlet are not tightly sealed Take down the one way valve and seal with sealant Leakage from the connection of chimney and cover Take chimney down and seal Lights not working Broken or faulty bulbs Replace blubs as per this instruction Insufficient suction The distance between the cooker hood and the gas top is too far Refit the ...

Page 9: ... panel can be cleaned using warm soapy water Ensure the cloth is clean and well wrung before cleaning Use a dry soft cloth to remove any excess moisture left after cleaning Important Using neutral detergents and avoid using harsh cleaning chemicals strong household detergents or products containing abrasives as this will affect the appearance of the appliance and potentially remove any printing of...

Page 10: ... FILTER Activated carbon filter can be used to trap odors Normally the activated carbon filter should be changed every 3 to 6 months according to your cooking habit The installation procedure of activated carbon filter is as below 1 Remove the grease filter 2 Take away the filter cloth from the back of the grease filter 3 Fix the carbon filter on the back of the grease filter with the small steel ...

Page 11: ...tion does not come in contact with the blub as this can reduce the life of the blub Note Before changing the lights that the cooker hood can be isolated from the supply mains by means of a plug or an all pole switch Protect against danger when changing lights such as wearing gloves Changing the light Remove the grease filter Loosen the 2pcs ST4 8mm screws from the lighting panel then take out the ...

Page 12: ...formation please contact your local or regional authorities NOTE The following shows how to reduce total environmental impact e g energy use of the cooking process 1 Install the cooker hood in a proper place where there is efficient ventilation 2 Clean the cooker hood regularly so as not to block the airway 3 Remember to switch off the cooker hood light after cooking 4 Remember to switch off the c...