10
In order to install the activated carbon filter, the aluminium filter should be detached
first.
1. Put the carbon filter on the back side of the aluminium filter.
2. Insert the steel wire into the frame of the aluminium filter, one on each side. You
need to bend it to insert into the other end of the frame.
3. Make sure the steel wire fix the carbon filter onto the aluminium filter.
NOTE:
Make sure the filter is securely locked. Otherwise, it would loosen and cause
danger.
When activated carbon filter attached, the suction power will be lowered.
BULB REPLACEMENT
Important :
The bulb must be replaced by the manufacturer, its
service agent or similarly qualified persons.
Always switch off the electricity supply before
carrying out any operations on the appliance. When
handling bulb, make sure it has completely cooled
down before any direct contact with hands.
When handling bulbs hold with a cloth or gloves to
ensure perspiration does not come in contact with
the bulb as this can reduce the life of the bulb.
Note:
Before changing the lights, make sure that the appliance is turned off and
unplugged.
Protect against danger when changing lights, such as wearing gloves.
Changing the light
Loosen the 2pcs ST4*8mm self-tapping screw from the lighting panel, take out
the lighting fixture.
Disassembly the 3pcs ST3*12mm screws on the terminal box cover and take
down the wire cover.
Pull out the terminal from the PCB terminal block, disconnect the wire connector
and
replace the lamp.
•
ILCOS D code for this lamp is: DBS-2/65-H-120/33
– LED modules –rectangle lamp
– Max wattage: 2 W
– Voltage range: AC
11
0-240V
– Dimensions: