21
3. The induction hotplate shall be installed such that better heat radiation can be ensured to enhance its reliability.
4. The wall and induced heating zone above the table surface shall withstand heat.
5. To avoid any damage, the sandwich layer and adhesive must be resistant to heat.
6. A steam cleaner is not to be used.
9.7
Connecting the hob to the mains power supply
This hob must be connected to the mains power supply only by a suitably qualified person. Before connecting the hob to the mains
power supply, check that:
1. The domestic wiring system is suitable for the power drawn by the hob.
2. The voltage corresponds to the value given in the rating plate
3. The power supply cable sections can withstand the load specified on the rating plate.
To connect the hob to the mains power supply, do not use adapters, reducers, or branching devices, as they can cause overheating
and fire.
The power supply cable must not touch any hot parts and must be positioned so that its temperature will not exceed 75
˚
C at any
point.
Check with an electrician whether the domestic wiring system is suitable without alterations. Any alterations must only be made by a
qualified electrician.
The power supply should be connected in compliance with the relevant standard, or a single-pole circuit breaker. The
method of connection is shown below.
•
If the cable is damaged or to be replaced, the operation must be carried out the by after-sale agent with dedicated
tools to avoid any accidents.
•
If the appliance is being connected directly to the mains an omnipolar circuit-breaker must be installed with a
minimum opening of 3mm between contacts.
•
The installer must ensure that the correct electrical connection has been made and that it is compliant with safety
regulations.
•
The cable must not be bent or compressed.
•
The cable must be checked regularly and replaced by authorised technicians only.
•
The yellow/green wire of the power supply cable must be connected to the earth of both power supply and appliance
terminals.
•
The manufacturer cannot be held responsible for any accidents resulting from the use of an appliance which is not
connected to earth, or with faulty earth connection continuity.
•
If the appliance has a socket outlet, it must be installed so that the socket outlet is accessible.
The bottom surface and the power cord of the hob are not accessible after installation.
220-240V~
220-240V~
Brown
Blue
Green/Y
ellow