Enter 109 End
*/$%ENTR* *ZEND*
Setting up your Operation Modes
7
7-2-1-24.
Set Time Delay for a Record for HID
This parameter refers to the amount of elapsed time to delay transmitting a record. Please
follow the below steps to set time delay for transmitting a record if the associated
operations are performed using USB HID interface.
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
StdHidTxGap
Time barcode to configure delay time for a record for HID.
(3)
Please refer to Decimal/Hexadecimal Table in the appendix to scan decimal value
representing the desired value in the range of 0 to 255. For instance, to defer
transmitting a digit for 0.2 seconds, scan
2
first and then
0
to assign the specified
decimal value “20”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Scan
End
barcode to complete the configuration.
*ABBE0*
StdHidTxGapTime
ABBE0
(Length: 1 digit / Range: 0-255/ Unit: 10ms)