Enter 122 End
*/$%ENTR* *ZEND*
Setting up your Operation Modes
7
7-2-2-20.
Set Standby Duration
After lengthy idleness, the device will first be put into standby state in which the machine
is still able to react to the emergent request yet running in lower power consumption. This
parameter refers to the amount of time allocated for the device to stay in standby before
being totally shut down.
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
StandbyTime
barcode to configure idle duration.
(3)
Please refer to Decimal/Hexadecimal Table in the appendix to scan decimal value
barcodes representing the desired value in the range of 0 to 255. For instance, to
set Standby duration to be 15 seconds, scan
1
first and then
5
to assign the
specified decimal value “15”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Scan
End
barcode to complete the configuration.
*B3FE0*
StandbyTime
B3FE0
(Length: 1 digit / Range: 0-255/ Unit: 1000ms)