Enter 199 End
*/$%ENTR* *ZEND*
Configuring Symbology
8
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
AuPostUDSI
barcode to tailor Code ID for AuPost to your needs.
(3)
Please refer to ASCII Code Table and Decimal/Hexadecimal Table in the appendix
to scan hexadecimal value barcodes representing the desired string which has to be
at most 2 characters in length. For instance, to set its Code ID to be “Au”, scan
4,
1, 7,
and then
5
to assign the specified hexadecimal value “4175”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Scan
End
barcode to complete the configuration.
8-3.
Aztec
8-3-1
Enable/Disable Aztec
Scan the appropriate barcode to determine whether or not to enable Aztec.
8-3-2
Configure Length Qualification
With length qualification the scanner will filter out the inappropriate barcodes whose lengths
are out of range. Scan
Min
barcode to specify the minimum length which the valid code at
least has to be;
Fixed
barcode requires the scanned code length to necessarily agree with
certain fixed number
;
Min/Max
barcode is to confirm whether the barcode length falls in
between maximum and minimum. However, to make this parameter work effectively, you
have to configure the length scale simultaneously. Please refer to
Section
8-3-4
for more
details about configurations of the length scale.
*53401*
Enable
53401
*53400*
Disable
53400
*53530*
Min
53530
*53531*
Fixed
53531