Enter 224 End
*/$%ENTR* *ZEND*
Configuring Symbology
8
the device will only decode the Code128 barcodes which contain check digit to
authenticate the decoded barcodes. Scan the appropriate barcode to determine whether to
verify check digit.
8-11-8.
Configure Length Qualification
With length qualification the scanner will filter out the inappropriate barcodes whose
lengths are out of range. Scan
Min
barcode to specify the minimum length which the valid
code at least has to be;
Fixed
barcode requires the scanned code length to necessarily agree
with certain fixed number
;
Min/Max
barcode is to confirm whether the barcode length
falls in between maximum and minimum. However, to make this parameter work
effectively, you have to configure the length scale simultaneously. Please refer to
Section
8-11-13
for more details about configurations of the length scale.
8-11-9.
Transmit AIM Identifier
AIM Identifier is a set of characters prefixed to decoded message in order to denote the
symbology type. Scan the appropriate barcode to determine whether to display AIM
identifier as part of transmitted barcodes.
*43530*
Min
43530
*43531*
Fixed
43531
*43532*
Min/Max
43532
*434C1*
French CIP
434C1
*434C0*
Disable
434C0
*C6001*
Enable
C6001
*C6000*
Disable
C6000