Enter 262 End
*/$%ENTR* *ZEND*
Configuring Symbology
8
8-23-4
Configure Length Qualification
With length qualification the scanner will filter out the inappropriate barcodes whose
lengths are out of range. Scan
Min
barcode to specify the minimum length which the
valid code at least has to be;
Fixed
barcode requires the scanned code length to
necessarily agree with certain fixed number
;
Min/Max
barcode is to confirm whether the
barcode length falls in between maximum and minimum. However, to make this
parameter work effectively, you have to configure the length scale simultaneously. Please
refer to
Section 8-23-6
for more details about configurations of the length scale.
8-23-5
Set Code ID for MSI
A user-defined Code ID functions as an identity for a specific barcode type to be
differentiated from others. It is especially helpful while you are dealing with more than
one type of barcodes at the same time. Scan the barcode below to customize your own
Code ID for MSI.
Procedure
(1)
Scan
Enter
barcode.
(2)
Scan
UDSI
barcode to tailor Code ID for MSI to your needs.
(3)
Please refer to ASCII Code Table and Decimal/Hexadecimal Table in the
appendix to scan hexadecimal value barcodes representing the desired string
which has to be at most 2 characters in length. For instance, to set its Code ID to
be “MI”, scan
4, D, 4,
and then
9
to assign the specified hexadecimal value
“4D49”.
(4)
Scan
SET
barcode to complete the variable-binding operation.
(5)
Scan
End
barcode to complete the configuration.
*46C02*
UDSI
46C02
*46530*
Min
46530
*46531*
Fixed
46531
*46532*
Min/Max
46532
(Length: 2 digits)