Enter 268 End
*/$%ENTR* *ZEND*
Configuring Symbology
8
8-26.
Plessey
8-26-1.
Enable/Disable Plessey
Scan the appropriate barcode to determine whether to enable Plessey.
8-26-2.
Transmit Check Digit
Scan the appropriate barcode to determine whether to transmit the check digit.
8-26-3.
Configure Length Qualification
With length qualification the scanner will filter out the inappropriate barcodes whose
lengths are out of range. Scan
Min
barcode to specify the minimum length which the
valid code at least has to be;
Fixed
barcode requires the scanned code length to
necessarily agree with certain fixed number
;
Min/Max
barcode is to confirm whether the
barcode length falls in between maximum and minimum. However, to make this
parameter work effectively, you have to configure the length scale simultaneously. Please
refer to
Section 8-26-5
for more details about configurations of the length scale.
*47541*
Enable
47541
1
*47540*
Disable
47540
*47401*
Enable
47401
*47400*
Disable
47400
*47530*
Min
47530
*47531*
Fixed
47531