5. General Setting
5: General Configuration Setting
5-2-1-5 Transmission Char Delay
After setting the number of characters transmitted into the Delay Time
*37W+*
5-2-1-6 Transmission Char Gap Time
This function can set Delay Time between 2 characters.
*47X+*
Configuration Range
Default Setting
0 ~ 255
0
Procedure
(A) Scan “Enter” barcode
(B) Scan “Transmission Char Delay” barcode
(C) Scan parameters from Hexadecimal / Decimal table
(D) Scan “OK“ barcode
(E) Scan “End” barcode
Configuration Range
Unit
Default Setting
0 ~ 255 ms
1ms
0 ms
Procedure:
Example:
(A) Scan “Enter” barcode
(B) Scan “Transmission Char Gap
Time” barcode
(C) Scan parameters from
Hexadecimal / Decimal table
(D) Scan “OK“ barcode
(E) Scan “End” barcode
If configuration is 2 ms, the
parameter value is 2 ms / 1 ms = 2