7
Frequent
Question
Q: Why scanner block the keyboard operation?
A: Check the cable connection with your equipment, or
re-plug in calbe with your reader. Then turn power on
again.
Q: If scanner has a good read beep but nothing
transferring after read a label.
A: Using the Setting List at
9 to show what current
setting of scanner is, or reset to Default, (or select
right Interface default if scanner has been changed
into another interface used), then re-program
scanner again.
Q: If scanner needs to read single digit code.
A: Refer to Min. code length of code option and set it to
be "01" for single code readable.
Q: If scanner isn't able to discriminate an unknown
label, but read manual very well.
A: Refer to Code Name Transmission at
17 to set
Enable, read a barcode label, then you will know
what symbology is read. Beside, it maybe need to
verify checksum. Refer to verify checksum of code
option and set Enable.
Q: If scanner transfers character very slow or loses
some characters on screen in keyboard interface
after reading a label.
A: You may set caps lock to be Alt+Keypad at
10 to
transmit scan code. Otherwise, it maybe mis-match
of transmission rate. Therefore, you can adjust an
appropriate Inter-char. Delay to match your
equipment. See
11.
(
Please contact with your dealer if scanner dose not
work properly.
Frequent
Question
8
Q: If scanner dosen't need an Enter character
addition after each barcode label transmission.
A: Refer to postamble transmission at
33, then set
Disable.
Q: If scanner want to read a label as function key
for your apprication.
A: Refer to function key simulation at
11 and set
Enable, then scanner can transmit a code as
function key. It is used for keyboard interface only.
Beside, you must make sure that a label is encoded
as function key, and its ASCII code is from 00
16
to
1F
16.
Please refer to ASCII code table at
35.
Q: Could I change scanner into different type
interface directly?
A: You can change factory interface default nto other
type interface. By plug-in different cable, program
scanner and set right interface to exit, then the
scanner will be change into different type interface.
However, you must make sure what cable you need.
Q: How to set
Specific Adjustments
functions?
A: For example1: Set code 39 Min. code length at
35
to be "01" for signal code readable.
Min. code length (00-48) range form 0 up to 48 digits.
PROGRAM
Ö
Min. Code Length
Ö
0
Ö
1
Ö
SET
Ö
EXIT
For example2: Set keyboard Inter-char. Delay at
11 to be "10" for match your equipment.
Inter-char. Delay (00-99*1ms) range from 0 to 99 ms.
PROGRAM
Ö
Inter-char. Delay
Ö
1
Ö
0
Ö
SET
Ö
EXIT
For example3: Set Code ID of UPC-A at
19 to be
"A" for ASCII code.
PROGRAM
Ö
Code ID
Ö
4
Ö
1
Ö
SET
Ö
EXIT