EdgeAccess
®
Universal Chassis System
L322 Fast Ethernet Media Converters
1-3
To install CLIMs in a UCS 1000 or UCS 1001 chassis, you must use a Model 1230 Bus Access
Module (BAM); however, you can install CLIMs directly in a UCS 1002 or Model 1030. See
Figure 2.
•
The UCS 1000 Chassis can hold up to 15 model 1230 BAMs with up to two CLIMs per BAM.
This allows a total of 30 CLIMs per UCS 1000.
•
The UCS 1001 Chassis can hold up to two model 1230 BAMs with up to two CLIMs per BAM.
This allows a total of 4 CLIMs per UCS 1001.
•
The UCS 1002 Chassis directly hosts up to 14 CLIMs, or 13 CLIMs with the optional DMM
installed.
•
The Model 1030 Standalone Enclosure holds one CLIM.
All CLIMs are hot swappable; they can be inserted or removed at any time without disrupting the data
transfer of other modules in the chassis.
Note: The Chassis Interconnect Module (CIM) must be present in the chassis in order for the DMM
to recognize the L322 modules.