COPYRIGHT © 2001 CANON INC. CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
4-83
4. MECHANICAL SYSTEM
3. Installing the Process Unit
1)
Remove all developing assemblies, and install the protection sheet [1] to each photosensitive drum.
Figure 4-910A
2)
Set the developing assembly [2] in the process unit.
•
Do not touch the drum contact
face.
•
Dry wipe it with lint-free paper
before use.
Figure 4-911A
[1]
[1]
M/C/Bk
photosensitive
drum
Check to see that
the edge of white
paper is bent down.
Plastic film
Y photosensitive drum
[2]