COPYRIGHT © 2001 CANON INC. CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
4-85
4. MECHANICAL SYSTEM
B. Cleaning Assembly
1. Separating the Developing
Assembly and the
Cleaning Unit
1)
Remove one screw [1] each from the front and
rear side plates of the developing assembly/
cleaning assembly; then, shift the cleaning
unit [2] to the rear to separate.
Figure 4-901B
Figure 4-902B
2. Removing the Cleaning Blade
1)
Remove the developing assembly/cleaning
unit from the copier (See chapter 4. IX.
PROCESS UNIT SYSTEM, A-2. Removing
the Developing Assembly/Cleaning Unit).
2)
Remove the two screws [1], and remove the
cleaning blade [2] together with its support
plate.
Figure 4-903B
3. When Replacing the Cleaning
Blade
The cleaning blade comes coated with
lubricant. However, be sure to perform the
following to ensure an even coating of lubricant:
1)
Wrap lint-free paper around a finger, and
remove the lubricant from the edge [3] of the
blade, i.e., where it will come into contact with
the drum.
Be sure not to force the paper to avoid
damaging the edge.
Figure 4-904B
[1]
[2]
[1]
[1]
[2]
[1]
[3]
Summary of Contents for 1000S