7-196
COPYRIGHT © 2001 CANON INC. CANON CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
7. TROUBLESHOOTING IMAGE FAULTS/MALFUNCTIONS
4. DENS (developer density)
<M>
<S>
<R>
<P>
<F>
ADJUST
COUNTER
OPTION
TEST
DENS
FUNC
DISP
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx
DENS-M
DENS-C
DENS-Y
REF-Y
REF-M
REF-C
1/3
Item
DENS-Y/M/C
REF-Y/M/C
Description
Indicates the discrepancy of the density of the devel-
oper on the developing cylinder (each color) in refer-
ence to the target value in %.
+:
Darker than target value.
–:
Lighter than target value.
The value is the result of computations based on SGNL
and REF stored under ATR-INIT and SGNL and REF
on the screen.
Indicates the measurement (AD conversion) of the
reference signal (each color).
Measurements are taken for each copy run.
Remarks
Unit = 0.1%
Normal if between - 20
and + 20.