7
7
7-8
7-8
Error Code > Error Code > Error Code Details
Error Code > Error Code > Error Code Details
Ecode
Detail
Code
Item
Description
E583 8002 Title
Tray Auxiliary Guide Motor (M6) error
Description The Tray Auxiliary Guide Motor (M6) was driven for 1.8 seconds, but the
Tray Auxiliary Guide could not be detected by the Tray Auxiliary Guide
HP Sensor (S6).
Remedy
1. Check the connector connection of the Tray Auxiliary Guide HP
Sensor (S6) or the Tray Auxiliary Guide Motor (M6).
2. Check for open circuit of the Harness of the Tray Auxiliary Guide HP
Sensor (S6) or the Tray Auxiliary Guide Motor (M6).
3. Replace the Tray Auxiliary Guide HP Sensor (S6).
4. Replace the Tray Auxiliary Guide Motor (M6).
5. Replace the Finisher Controller PCB.
E719 0000 Title
Error in communication with the Copy Card Reader-F1 (serial
communication)
Description Card Reader was not connected at department management setting.
Remedy
1. Check the connection with the Card Reader.
2. Remove the Card Reader, and execute the following: service mode >
#CLEAR > ERR > E719.
E736 0000 Title
Fax Board mismatch error
Description Combination of the Fax Board type and the country was mismatched.
Remedy
This error occurred in the following cases.
- Fax Board for non-Chinese models was installed to a Chinese model.
- Fax Board for Chinese models was installed to a non-Chinese model.
- For Chinese models, replace the Fax Board with that for Chinese
models.
- For non-Chinese models, replace the Fax Board with that for non-
Chinese models.
E804 0000 Title
Power Supply Cooling Fan (FM4) error
Description A lock signal was detected for 5 seconds while the Power Supply
Cooling Fan (FM4) was being stopped.
*The same status was detected again after executing an error retry.
Remedy
1. Disconnect and then connect the connector (J209) on the DC
Controller PCB (PCB1) to check the connection.
2. Replace the Power Supply Cooling Fan (FM4).
3. Replace the DC Controller PCB (PCB1).
E804 0001 Title
Error in rotation of the Power Supply Cooling Fan (FM4)
Description A lock signal could not be detected for 5 seconds while the Power
Supply Cooling Fan (FM4) was being driven.
*The same status was detected again after executing an error retry.
Remedy
1. Disconnect and then connect the connector (J209) on the DC
Controller PCB (PCB1) to check the connection.
2. Replace the Power Supply Cooling Fan (FM4).
3. Replace the DC Controller PCB (PCB1).
Ecode
Detail
Code
Item
Description
E805 0000 Title
Heat Exhaust Fan (Rear) (FM6) error
Description A lock signal was detected for 5 seconds while the Heat Exhaust Fan
(Rear) (FM6) was being stopped.
*The same status was detected again after executing an error retry.
Remedy
1. Disconnect and then connect the connector (J212) on the DC
Controller PCB (PCB1) to check the connection.
2. Replace the Heat Exhaust Fan (Rear) (FM6).
3. Replace the DC Controller PCB (PCB1).
E805 0001 Title
Error in rotation of the Heat Exhaust Fan (Rear) (FM6)
Description A lock signal could not be detected for 5 seconds while the Heat
Exhaust Fan (Rear) (FM6) was being driven.
*The same status was detected again after executing an error retry.
Remedy
1. Disconnect and then connect the connector (J212) on the DC
Controller PCB (PCB1) to check the connection.
2. Replace the Heat Exhaust Fan (Rear) (FM6).
3. Replace the DC Controller PCB (PCB1).
E805 0002 Title
Heat Exhaust Fan (Front) (FM5) error
Description A lock signal was detected for 5 seconds while the Heat Exhaust Fan
(Front) (FM5) was being stopped.
*The same status was detected again after executing an error retry.
Remedy
1. Disconnect and then connect the connector (J212) on the DC
Controller PCB (PCB1) to check the connection.
2. Replace the Heat Exhaust Fan (Front) (FM5).
3. Replace the DC Controller PCB (PCB1).
E805 0003 Title
Error in rotation of the Heat Exhaust Fan (Front) (FM5)
Description A lock signal was detected for 5 seconds while the Heat Exhaust Fan
(Front) (FM5) was being driven.
*The same status was detected again after executing an error retry.
Remedy
1. Disconnect and then connect the connector (J212) on the DC
Controller PCB (PCB1) to check the connection.
2. Replace the Heat Exhaust Fan (Front) (FM5).
3. Replace the DC Controller PCB (PCB1).
E820 0000 Title
Developing Cooling Fan (Front) (FM7) error
Description A lock signal was detected for 5 seconds while the Developing Cooling
Fan (Front) (FM7) was being driven.
*The same status was detected again after executing an error retry.
Remedy
1. Disconnect and then connect the connector (J209) on the DC
Controller PCB (PCB1) to check the connection.
2. Replace the Developing Cooling Fan (Front) (FM7).
3. Replace the DC Controller PCB (PCB1).
Summary of Contents for 1750
Page 12: ...Update Firmware XXV Volume Control XXV Backup Data XXVI...
Page 17: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name...
Page 235: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code...
Page 250: ...8 8 Service Mode Service Mode Outline Details of Service Mode...
Page 333: ...Service Tools General Timing Chart General Circuit Diagram List of User Mode Appendix...